4 / 7 page ![]() MODEL: AD2LC AD2LC SPECIFICATIONS ES-1388 Rev.14 Page 4/7 https://www.m-system.co.jp/ PARAMETER LIST It is available to configure or confirm settings shown below by using front key pad. ITEM MDF. CODE DATA CONTENTS DEFAULT P N/A -9999 – 9999 (-FFFF – FFFF) Output display in engineering unit, BCD (as set in ITEM 17/18) ( ) for binary, offset binary, two’s complement, re ected binary ---- 01 1, 2 Modi cation code 1 : Data indication only. 2 : All parameters are modi able. 1 02 N/A 0 – 99 Status indication (“0” is normally indicated.) ---- 03 N/A 0, 1, 2 Input range code 0 : S1 (0.0 – 3.0mV/V) 1 : S2 (0.0 – 10.0mV/V) 2 : S3 (0.0 – 30.0mV/V) User speci ed 04 2 0.1 – 12.0 Excitation voltage (V) 1.0V 05 2 0.010 – 3.000 0.010 – 9.999 0.10 – 30.0 Sensor sensitivity S1 : 0.0 – 3.0mV/V S2 : 0.0 – 10.0mV/V S3 : 0.0 – 30.0mV/V Used when adjusting the sensor sensitivity by its rating value. Set ITEM 06 before 05. 3.000 9.999 30.00 06 2 -30.00 – 30.00 -99.99 – 99.99 -300.0 – 300.0 0% input voltage S1 : -30.00 – 30.00mV S2 : -99.99 – 99.99mV S3 : -300.0 – 300.0mV Sensor’s zero adjustment. Approximate offset voltage. 07 2 -30.00 – 30.00 -99.99 – 99.99 -300.0 – 300.0 100% input voltage S1 : -30.00 – 30.00mV S2 : -99.99 – 99.99mV S3 : -300.0 – 300.0mV Used when adjusting the sensor sensitivity with an actual load. Set ITEM 06 before 07. 08 2 10.0 – 100.0 Load ratio (%) Used when adjusting the sensor sensitivity with an actual load. 100.0 09 2 -999.9 – 999.9 Tare adjustment (%) 0.0 10 N/A -15.0 – 115.0 Input indicated in % (of the range set in ITEM 05/06/07) ---- 11 2 -99.99 – 99.99 Zero adjustment (%) ( ne adj. of the value set in ITEM 05/06/07) 0.00 12 2 0.000 – 9.999 Gain adjustment ( ne adj. of the value set in ITEM 05/06/07) 1.000 13 2 0, 1, 2, 3, 4 Moving average (200 msec./sampling) 0: No 1: 4 samples 2: 8 samples 3: 16 samples 4: 32 samples 0 14 2 0, 1, 2, 3 Contact input function 0 : Tare adjustment 1 : Peak hold 2 : Valley hold 3 : Sample hold 0 15 2 10 – 99 Power ON-delay time (seconds) 10 16 2 0, 1 – 60 Power-saving mode 0 : Continuous display 1 – 60 : Time before display turned off (minutes) 10 17 18 2 2 -9999 – 9999 -9999 – 9999 BCD Display range scaling 0% *1 Display range scaling 100% *1 -1000 1000 17 18 2 2 -7FFF – 7FFF -7FFF – 7FFF Binary Display range scaling 0% *1 Display range scaling 100% *1 -7FFF 7FFF |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |