  M2MNV-22-R2 Datasheet HTML 1Page - M-System Co.,Ltd. M2MNV-22-R2 Datasheet HTML 2Page - M-System Co.,Ltd. M2MNV-22-R2 Datasheet HTML 3Page - M-System Co.,Ltd. M2MNV-22-R2 Datasheet HTML 4Page - M-System Co.,Ltd. M2MNV-22-R2 Datasheet HTML 5Page - M-System Co.,Ltd. M2MNV-22-R2 Datasheet HTML 6Page - M-System Co.,Ltd.  
Zoom Inzoom in Zoom Outzoom out
 5 / 6 page
background image
MODEL: M2MNV
M2MNV SPECIFICATIONS
ES-5095 Rev.9 Page 5/6
http://www.m-system.co.jp/
SWITCHING OPERATIONS
1
2
4
5
7
8
1
2
4
5
7
8
Current Signal (no receiving resistor)
Power : OFF
Switching command : OFF (open)
1
2
4
5
7
8
1
2
4
5
7
8
Power : ON
Switching command : OFF (open)
1
2
4
5
7
8
1
2
4
5
7
8
Power : ON
Switching command : ON (short)
Current Signal (receiving resistor 50 Ω)
Voltage Signal
Current Signal (no receiving resistor)
Transition (ON to OFF, OFF to ON) Status
Power : ON
Switching command : OFF to ON
or
Power : ON
Switching command : ON to OFF
Current Signal (receiving resistor 50 Ω)
Voltage Signal
*1. Resistor is provided only for the input code 2: Current signal (receiving resistor 50 Ω).
*1. Resistor is provided only for the input code 2: Current signal (receiving resistor 50 Ω).
*1
*1
*1
*1
1
2
4
5
7
8
1
2
4
5
7
8
*1
*1
*1
*1
• Switching Status
When the switching command contact is switched from
OFF to ON or from ON to OFF, the signal channel is
switched only after all photo MOSFET relays turn on
(closed).
When the switching command contact is switched from
OFF to ON or from ON to OFF, the signal channel is
switched only after all photo MOSFET relays turn off
(open).
INTERLOCKING SWITCHING CONTROL (single-pole contact)
Single contact is used to switch from Signal Channel 1 (A1 – B1) to Signal Channel 2 (A2 – B1) and vice versa.
CHANNEL 1 (A1)
CHANNEL 2 (A2)
Terminal 3 – 9 OFF (open)
OFF
ON
Terminal 3 – 9 ON (closed)
ON
OFF
Status LED turn on when the respective channels are alive.
INDEPENDENT SWITCHING CONTROL (double-pole contact)
Double contacts are used to independently switch Signal Channel 1 (A1 – B1) and Signal Channel 2 (A2 – B1).
CHANNEL 1 (A1)
CHANNEL 2 (A2)
Terminal 3 – 9 OFF (open)
OFF
----
Terminal 3 – 9 ON (closed)
ON
----
Terminal 6 – 9 OFF (open)
----
OFF
Terminal 6 – 9 ON (closed)
----
ON
Status LED turn on when the respective channels are alive.



Html Pages

1 2 3 4 5 6


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com