| 数据搜索系统,热门电子元器件搜索 |
|
R3-ND2-R 数据表(PDF) 4 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3-ND2-R 数据表(HTML) 4 Page - M-System Co.,Ltd. |
|
4 / 7 page ![]() MODEL: R3-ND2 R3-ND2 SPECIFICATIONS ES-8381 Rev.20 Page 4/7 https://www.m-system.co.jp/ TRANSMISSION DATA DESCRIPTIONS The DIP SW located at the side of the module specifies each I/O module's data allocation (occupied data area). For example, when the data areas are assigned as shown below: Module 1 4 Module 2 4 Module 3 4 Module 4 1 Module 5 1 Module 6 1 Module 7 1 Then the I/O data are assigned as in the figures below: Module Status, Error Status and Data Error Status are assigned to +32, +33 and +34 respectively. Each module can handle either input or output data. Input and output cannot be mixed in one module. Input data from the master device is transferred to the module's output data area. The master device can read from the output data area the data it has set. • Module Status indicates whether individual I/O modules are mounted or not. The bit corresponding to the mounted slot turns to “1,” and the unmounted slot to “0.” • Error Status indicates error status for each module as described below. The bit corresponding to such module turns to “1.” R3-TSx, R3-RSx, R3-US4: Input burnout R3-DA16A: Power input in error or disconnected R3-YSx: Output current error (e.g. load unconnected) • Data Error Status indicates overrange (R3-US4: out of -10% to +110%; the other types: out of -15% to +115%) status for each module. The bit corresponding to such module turns to “1.” 0 15 +0 +2 +4 +6 +8 +10 +12 +14 +16 +32 +34 Module 1 Module 2 Module 3 Module 4 Module 5 Module 6 Module 7 Module Status Error Status Data Error Status Begin Address 0 15 +0 +2 +4 +6 +8 +10 +12 +14 +16 +31 Module 1 Module 2 Module 3 Module 4 Module 5 Module 6 Module 7 Begin Address ■ OUTPUT DATA The figure below shows the allocation of the data sent from the network module to the master. ■ INPUT DATA The figure below shows the allocation of the data sent from the master to the network module. R3-PC16A: External power supply in error or disconnected |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |