| 数据搜索系统,热门电子元器件搜索 |
|
E5CC-RX2ASM-800 数据表(PDF) 19 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CC-RX2ASM-800 数据表(HTML) 19 Page - Omron Electronics LLC |
|
19 / 36 page ![]() E5EC-800 19 Communications Specifications * The baud rate, data bit length, stop bit length, and vertical parity can be in- dividually set using the Communications Setting Level. Current Transformer (Order Separately) Ratings Heater Burnout Alarms and SSR Failure Alarms *1. For heater burnout alarms, the heater current will be measured when the control output is ON, and the output will turn ON if the heater current is lower than the set value (i.e., heater burnout detection current value). *2. For SSR failure alarms, the heater current will be measured when the control output is OFF, and the output will turn ON if the heater current is higher than the set value (i.e., SSR failure detection current value). *3. The value is 30 ms for a control period of 0.1 s or 0.2 s. *4. The value is 35 ms for a control period of 0.1 s or 0.2 s. Transmission line connection method RS-485: Multipoint Communications RS-485 (two-wire, half duplex) Synchronization method Start-stop synchronization Protocol CompoWay/F, or Modbus Baud rate 19200, 38400, or 57600 bps Transmission code ASCII Data bit length* 7 or 8 bits Stop bit length* 1 or 2 bits Error detection Vertical parity (none, even, odd) Block check character (BCC) with CompoWay/F or CRC-16 Modbus Flow control None Interface RS-485 Retry function None Communications buffer 217 bytes Communications response wait time 0 to 99 ms Default: 20 ms Dielectric strength 1,000 VAC for 1 min Vibration resistance 50 Hz, 98 m/s2 Weight E54-CT1: Approx. 11.5 g, E54-CT3: Approx. 50 g Accessories (E54-CT3 only) Armatures (2) Plugs (2) CT input (for heater current detection) Models with detection for singlephase heaters: One input Models with detection for singlephase or three-phase heaters: Two inputs Maximum heater current 50 A AC Input current indica- tion accuracy ±5% FS ±1 digit max. Heater burnout alarm setting range *1 0.1 to 49.9 A (in units of 0.1 A) Minimum detection ON time: 100 ms *3 SSR failure alarm setting range *2 0.1 to 49.9 A (in units of 0.1 A) Minimum detection OFF time: 100 ms *4 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |