| 数据搜索系统,热门电子元器件搜索 |
|
E5CC-RX2ASM-800 数据表(PDF) 27 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CC-RX2ASM-800 数据表(HTML) 27 Page - Omron Electronics LLC |
|
27 / 36 page ![]() E5CC/E5EC-800 27 Operation M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M 25 0 C 25 0 l.adj ins 0.0 c-p 8.0 c-i 233 c-d 40 M M M p 8.0 i 233 d 40 c-db 0.0 of-r 50.0 hys 1.0 chys 1.0 pmov 0 oapt 0 icpt 1 wtpt off pfpt off M chgp off M M sprt off ol-h 100.0 ol-l 0.0 at off cmwt off ct1 0.0 M hb1 0.0 lcr1 0 hs1 50.0 sp-0 0 sp-1 0 sp-2 0 sp-3 0 sp-4 0 sp-5 0 sp-6 0 sp-7 0 M sp-3 0 r-s run al-1 0 al1h 0 al1l 0 al-2 0 al2h 0 al2l 0 M o 0.0 c-o 0.0 25 0 a-m m-sp 0 ct-1 0.0 lcr1 0.0 PID Control only Press the S Key for at least 1 s. *1 Press the O Key or the S Key for at least 1 s. *1 Operation Level Power ON Starting in manual mode. Adjustment Level Press the O Key less than 1 s. Press the O Key less than 1 s. PV/MV Starting in automatic mode. Adjustment Level Display Displayed only once when entering adjustment level. Manual Control Level Press the S Key *2 Press the S Key *2 Press the O Key for at least 3 s. Press the O and M Keys for at least 3 s. Proportional Band (Cooling) Protect Level Note: The time ta ken to move to the protect level can be adjusted by changing the "Move to protect level time" setting. *1. When the PF Setting parameter is set to A-M. *2. When the PF Setting parameter is set to PFDP. *3. These parameters are displayed regardless of the setting of the Protocol Setting parameter. Move to Protect Level: Operation/Adjustment Protect: Initial Setting/Communications Protect: Setting Change Protect: Displayed only when a password is set. Restricts moving to protect level. Restricts displaying and modifying menus in operation, adjustment, and manual control levels. This protect level restricts movement to the initial setting, communicationssetting, and advanced function setting levels. Protects changes to setups by operating the front panel keys. PF Key Protect AT Execute/Cancel Communications Writing Heater Current 1 Value Monitor Leakage Current 1 Monitor Heater Burnout Detection 1 HS Alarm 1 SP 0 SP 1 SP 2 SP 3 SP 4 SP 5 SP 6 SP 7 Integral Time (Cooling) Derivative Time (Cooling) Dead Band Manual Reset Value Clear the offset during stabilization of P or PD control. Hysteresis (Heating) Hysteresis (Cooling) MV Upper Limit MV Lower Limit Hysteresis settings Process Value Input Shift Process Value/Set Point (1) Process Value/Set Point (2) Auto/Manual Switch PID 1 control only. Added for Auto/Manual Switch Display Addition. Heater Current 1 Value Monitor Leakage Current 1 Monitor Multi-SP Set Point Setting Alarm Value 1 Alarm Value Upper Limit 1 Alarm Value Lower Limit 1 Alarm Value 2 Alarm Value Upper Limit 2 Alarm Value Lower Limit 2 MV Monitor (Heating) MV Monitor (Cooling) Press the O and M Keys for at least 1 s. Proportional Band Integral Time Derivative Time PID settings SP Ramp Set Value RUN/STOP Display Changed Parameters Press the O Key less than 1 s. Communications Setting Level Note: Displayed only for models with communications. Changes are effective after cycling power or after a software reset. M M M len 7 sbit 2 prty even Communications Data Length *3 Communications Stop Bits *3 Communications Parity *3 Initial Setting Level Press the O Key for at least 3 s. Press the O Key for at least 1 s. Other than the Auto/Manual Switch display M M M M M Protocol Setting *3 Communications Unit No. *3 Communications Baud Rate *3 Send Data Wait Time *3 Maximum Communications Unit No. Area M M M M First Address Upper Word First Address Lower Word Receive Data Wait Time Upload Setting 1 M M M M Upload Setting 13 Download Setting 1 Download Setting 13 Copy M psel fins u-no 0 bps 57.6 sdwt 20 maxu 0 adrh 0 adrl 0 rwat 1000 area 0 up13 0 dn 1 0 dn13 1000 copy off up 1 0 M Communications Node Number unit 0 Parameters The related setting items in each level are described below. If you press the Mode Key at the last setting item, the display will return to the first setting item in the same level. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |