Absolute Maximum Ratings
V
SS = 0 V
Recommended Operating Conditions
V
SS = 0 V
Parameter
Symbol
Rating
Unit
Supply voltage
V
DD1
V
SS – 0.3 to VSS + 2.0
V
V
DD2
V
SS – 0.3 to VSS + 6.0
V
Input voltage range
V
FIN
V
SS – 0.3 to VDD + 0.3
V
Operating temperature range
T
PS
–30 to 60
oC
Storage temperature range
T
STG
–40 to 125
oC
Soldering temperature range
T
SLD
255
oC
Soldering time range
t
SLD
10
s
Parameter
Symbol
Value
Unit
min.
typ.
max.
Supply voltage range
V
DD1
0.95
1.0
2.0
V
V
DD2
2.4
3.0
3.6
V
Operating temperature
T
A
–30
25
60
oC