数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

71M6543HT-IGTR/F 数据表(PDF) 23 Page - Maxim Integrated Products

部件名 71M6543HT-IGTR/F
功能描述  Energy Meter ICs
PDF  75 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  MAXIM [Maxim Integrated Products]
网页  https://www.maximintegrated.com/en.html
标志 MAXIM - Maxim Integrated Products

71M6543HT-IGTR/F 数据表(HTML) 23 Page - Maxim Integrated Products

Back Button 71M6543HT-IGTR/F Datasheet HTML 19Page - Maxim Integrated Products 71M6543HT-IGTR/F Datasheet HTML 20Page - Maxim Integrated Products 71M6543HT-IGTR/F Datasheet HTML 21Page - Maxim Integrated Products 71M6543HT-IGTR/F Datasheet HTML 22Page - Maxim Integrated Products 71M6543HT-IGTR/F Datasheet HTML 23Page - Maxim Integrated Products 71M6543HT-IGTR/F Datasheet HTML 24Page - Maxim Integrated Products 71M6543HT-IGTR/F Datasheet HTML 25Page - Maxim Integrated Products 71M6543HT-IGTR/F Datasheet HTML 26Page - Maxim Integrated Products 71M6543HT-IGTR/F Datasheet HTML 27Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 75 page
background image
Maxim Integrated │ 23
71M6543FT/71M6543HT/
71M6543GT/71M6543GHT
Energy Meter ICs
www.maximintegrated.com
The performance of the IADC0-IADC1 pins can be
enhanced by enabling a preamplifier with a fixed gain of 8.
When the PRE_E bit = 1, IADC0-IADC1 become the inputs
to the 8x preamplifier, and the output of this amplifier is
supplied to the multiplexer. The 8x amplification is useful
when current sensors with low sensitivity, such as shunt
resistors, are used. With PRE_E set, the IADC0-IADC1
input signal amplitude is restricted to 31.25 mV peak.
When shunt resistors are used as current sense ele-
ments on all current inputs, the IADC0-IADC1 pins are
configured for differential mode to interface to a local
shunt by setting the DIFFA_E control bit. Meanwhile, the
IADC2-IADC7 pins are re-configured as digital balanced
pair to communicate with a 71M6x03 isolated sensor
interface by setting the RMT_E control bit. The 71M6x03
communicates with the 71M654xT using a bidirectional
digital data stream through an isolating low-cost pulse
transformer. The 71M654xT also supplies power to the
71M6x03 through the isolating transformer.
When using current transformers the IADC2-IADC7 pins
are configured as local analog inputs (RMT_E = 0). The
IADC0-IADC1 pins cannot be configured as a remote
sensor interface.
Input Multiplexer
When operating with local sensors, the input multiplexer
sequentially applies the input signals from the analog
input pins to the input of the ADC. One complete sampling
sequenceiscalledamultiplexerframe.Themultiplexerof
the 71M6543FT/HT/GT/GHT can select up to seven input
signals (three voltage inputs and four current inputs) per
multiplexer frame. The multiplexer always starts at state
1 and proceeds until as many states as determined by
MUX_DIV[3:0] have been converted.
The71M6543FT/HT/GT/GHTrequiresCEcodethatiswrit-
ten for the specific application. Moreover, each CE code
requiresspecificAFEandMUXsettingsinordertofunction
properly. Contact Maxim Integrated for specific information
about alternative CE codes.
For a polyphase configuration with neutral current sens-
ing using shunt resistor current sensors and the 71M6xx3
isolated sensors, as shown in Figure 3, the IADC0-IADC1
input must be configured as a differential input, to be con-
nected to a local shunt. The local shunt connected to the
IADC0-IADC1 input is used to sense the Neutral current.
The voltage sensors (VADC8-VADC10) are also directly
connected to the 71M6543FT/HT/GT/GHT and are also
routed though the multiplexer. Meanwhile, the IADC2-
IADC7 current inputs are configured as remote sensor
digital interfaces and the corresponding samples are not
routed through the multiplexer.
For a polyphase configuration with optional neutral current
sensing using Current Transformer (CTs) sensors, all four
current sensor inputs must be configured as differential
inputs. IADC2-IADC3 is connected to phase A, IADC4-
IADC5 is connected to phase B, and IADC6-IADC7
is connected to phase C. The IADC0-IADC1 current
sensor input is optionally used to sense the Neutral
current for anti-tampering purposes. The voltage sensors
(VADC8-VADC10), typically resistive dividers, are directly
connected to the 71M6543FT/HT/GT/GHT. No 71M6xx3
isolated sensors are used in this configuration and all
signals are routed though the multiplexer.
ThemultiplexersequenceshowninFigure 4 corresponds
to the configuration shown in Figure 3. The frame duration
is 13 CK32 cycles (where CK32 = 32,768Hz), therefore,
the resulting sample rate is 32,768 Hz/13 = 2,520.6Hz.
Figure 4. Multiplexer Sequence with Neutral Channel and Remote Sensors
CK32
MUX STATE0
1
2
3
45
SETTLE
MULTIPLEXER FRAME
MUX_DIV[3:0] = 6 CONVERSIONS
S
CROSS
MUX_SYNC
S
IN
UNUSED
UNUSED
VA
VB
VC



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com