| 数据搜索系统,热门电子元器件搜索 |
|
M28W320CB 数据表(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M28W320CB 数据表(HTML) 13 Page - STMicroelectronics |
|
13 / 42 page ![]() 13/42 M28W320CT, M28W320CB The suggested flow charts for programs that use the programming, erasure and program/erase suspend/resume features of the memories are shown from Figures 11, 12, 13, 14 and 15. Protection Register Program (PRP) The Protection Register Program uses two write cycles. The first command written is the protection program command C0h. The second write opera- tion latches the Address and the Data to be written to the Protection Register (see Protection Register and Security Block) and start the PE/C. Read op- erations output the Status Register content after the programming has started. The 64 bits user programmable Segment (85h to 88h) are pro- grammed 16 bits at a time, it can be protected by the user programming bit 1 of the Protection Lock register. The bit 1 of the Protection Lock register protect the bit 2 of the Protection Lock Register. Writing the bit 2 of the Protection Lock Register will result in a permanent protection of the Security Block. Attempting to program a previously protect- ed protection Register will result in a status regis- ter error (bit 1 and bit 4 of the status register will be set to ’1’). The protection of the Protection Register and/or the Security Block is not reversible. The Protection Register Program cannot be sus- pended. Block Protect (BP) The BP instruction use two write cycles. The first command written is the protection setup 60h. The second command is block Protect command 01h. The address within the block being protected must be given in order to write the protection state. If the second command is not recognized by the C.I the bit 4 and bit 5 of the status register will be set to in- dicate a wrong sequence of commands. To read the status register write the RSR command. Block Unprotect (BU) The instruction use two write cycles. The first com- mand written is the protection setup 60h. The sec- ond command is block Unprotect command d0h. The address within the block being unprotected must be given in order to write the unprotection state. If the second command is not recognized by the C.I the bit 4 and bit 5 of the status register will be set to indicate a wrong sequence of com- mands. To read the status register write the RSR command. Block Lock (BL) The instruction use two write cycles. The first com- mand written is the protection setup 60h. The sec- ond command is block Lock command 2Fh. The address within the block being Locked must be given in order to write the Locking state. If the sec- ond command is not recognized by the C.I the bit 4 and bit 5 of the status register will be set to indicate a wrong sequence of commands. To read the sta- tus register write the RSR command. Table 13. Program, Erase Times and Program/Erase Endurance Cycles (TA = 0 to 70°C or –40 to 85°C; VDD = 2.7V to 3.6V) Note: TA =25 °C. Parameter Test Condition s M28W320C Unit Min Typ (1) Max Word Program VPP =VDD 10 200 µs Double Word Program VPP = 12V ±5% 10 200 µs Main Block Program VPP = 12V ±5% 0.16 5 sec VPP =VDD 0.32 5 sec Parameter Block Program VPP = 12V ±5% 0.02 4 sec VPP =VDD 0.04 4 sec Main Block Erase VPP = 12V ±5% 1 10 sec VPP =VDD 110 sec Parameter Block Erase VPP = 12V ±5% 0.8 10 sec VPP =VDD 0.8 10 sec Program/Erase Cycles (per Block) 100,000 cycles |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |