8 / 18 page ![]() ELECTRONICS FCI Electronics Manual Part No. 415988-001 Issued: Date (03/12/99) Page 8 of 18 Rev. 05/07/01 ECR V10337 Revision B K\DCU\Manuals • • Check that the spring was not dislodged from the disconnect (box) portion of the terminal. • Check that the wire barrel seam is even and tightly closed. Figure 4. Correctly Crimped Terminal Next, obtain a crimp height micrometer and measure the areas of the terminal shown in Figure 5. If the crimp heights do not meet the specifications listed in “Specifications” on page 5, refer to the section for proper adjustment procedures of crimp height on page 15. Figure 5. Measuring Crimp Height of Terminal PDM: Rev:B Released STATUS: Printed: Dec 19, 2002 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|