| 数据搜索系统,热门电子元器件搜索 |
|
ADE7761AARS-REF 数据表(PDF) 18 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7761AARS-REF 数据表(HTML) 18 Page - Analog Devices |
|
18 / 24 page ![]() ADE7761A Rev. 0 | Page 18 of 24 Fault with Active Input Greater than Inactive Input If V1A is the active current input (that is, being used for billing), and the voltage signal on V1B (inactive input) falls below 93.75% of V1A, the fault indicator becomes active. Both analog inputs are filtered and averaged to prevent false triggering of this logic output. As a consequence of the filtering, there is a time delay of approximately 3 sec on the logic output FAULT after the fault event. The FAULT logic output is independent of any activity on outputs F1 or F2. Figure 28 shows one condition under which FAULT becomes active. Because V1A is the active input and it is still greater than V1B, billing is maintained on V1A, that is, no swap to the V1B input occurs. V1A remains the active input. V1B V1N V1A AGND FILTER AND COMPARE TO MULTIPLIER FAULT A B V1A V1B V1B < 93.75% OF V1A >0 <0 ACTIVE POINT – INACTIVE INPUT 6.25% OF ACTIVE INPUT 0V FAULT V1A V1B Figure 28. Fault Conditions for Active Input Greater than Inactive Input Fault with Inactive Input Greater than Active Input Figure 29 illustrates another fault condition. If the difference between V1B, the inactive input, and V1A, the active input (that is, being used for billing), becomes greater than 6.25% of V1B, the FAULT indicator becomes active and a swap over to the V1B input occurs. The analog input V1B becomes the active input. Again, a time constant of about 3 sec is associated with this swap. V1A does not swap back to the active channel until V1A is greater than V1B and the difference between V1A and V1B—in this order—becomes greater than 6.25% of V1A. However, the FAULT indicator becomes inactive as soon as V1A is within 6.25% of V1B. This threshold eliminates potential chatter between V1A and V1B. V1B V1N V1A AGND FILTER AND COMPARE TO MULTIPLIER FAULT A B V1A V1B V1A < 93.75% OF V1B >0 <0 ACTIVE POINT – INACTIVE INPUT 6.25% OF INACTIVE INPUT 0V FAULT + SWAP V1A V1B Figure 29. Fault Conditions for Inactive Input Greater than Active Input Calibration Concerns Typically, when a meter is being calibrated, the voltage and current circuits are separated, as shown in Figure 30. This means that current passes through only the phase or neutral circuit. Figure 30 shows current being passed through the phase circuit. This is the preferred option because the ADE7761A starts billing on the input V1A on power-up. The phase circuit CT is connected to V1A in Figure 30. Because there is no current in the neutral circuit, the FAULT indicator comes on under these conditions. However, this does not affect the accuracy of the calibration and can be used as a means to test the functionality of the fault detection. AGND V1B V1N V1A RF RF CF CF CT CT RB RB 0V V1A IB IB 1RB + VR = RF. VR1 RB1 RA1 V2P RF V2N CT CF V TEST CURRENT 240V rms Figure 30. Conditions for Calibration of Channel B If the neutral circuit is chosen for the current circuit in the arrangement shown in Figure 30, this may have implications for the calibration accuracy. The ADE7761A powers up with the V1A input active as normal. However, because there is no current in the phase circuit, the signal on V1A is zero. This causes a fault to be flagged and the active input to be swapped to V1B (neutral). The meter can be calibrated in this mode, but the phase and neutral CTs may differ slightly. Because under no-fault conditions all billing is carried out using the phase CT, the meter should be calibrated using the phase circuit. Of course, both phase and neutral circuits can be calibrated. MISSING NEUTRAL MODE The ADE7761A integrates a novel fault detection that warns and allows the ADE7761A to continue to bill in case a meter is connected to only one wire (see Figure 31). For correct operation of the ADE7761A in this mode, the VDD pin of the ADE7761A must be maintained within the specified range (5 V ± 5%). The missing neutral detection algorithm is designed to work over a line frequency of 45 Hz to 55 Hz. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |