19 / 24 page ![]() ADE7761A Rev. 0 | Page 19 of 24 V1B V1N V1A RF RF CF CF CT CT RB RB 0V V1A 1RB + VR = RF. VR1 RB1 RA1 V2P RF V2N CT CF LOAD 244V rms POWER GENERATOR IB Figure 31. Missing Neutral System Diagram The ADE7761A detects a missing neutral condition by continuously monitoring the voltage channel input (V2P − V2N). The FAULT pin is held high when a missing neutral condition is detected. In this mode, the ADE7761A continues to bill the energy based on the signal level on the current channel (see Figure 32). The billing rate or frequency outputs can be adjusted by changing the dc level on the MISCAL pin. V1A V1N V1B MISSING NEUTRAL GAIN ADJUSMTENT DIGITAL-TO- FREQUENCY CONVERTERS CF F1 F2 ZERO CROSSING DETECTION A > B B > A B <> A ADC ADC ADC MISCAL LPF HPF Figure 32. Energy Calculation in Missing Neutral Mode Important Note for Billing of Active Energy The ADE7761A provides pulse outputs—CF, F1, and F2— intended to be used for the billing of active energy. Pulses are generated at these outputs in two different situations. Case 1 : When the analog input V2P – V2N complies with the conditions described in Figure 34, CF, F1, and F2 frequencies are proportional to active power and can be used to bill active energy. Case 2 : When the analog input V2P – V2N does not comply with the conditions described in Figure 34, the ADE7761A does not measure active energy but a quantity proportional to kAh. This quantity is used to generate pulses on the same CF, F1, and F2. This situation is indicated when the FAULT pin is high. Analog Devices, Inc. cautions users of the ADE7761A about the following: • Billing active energy in Case 1 is consistent with the understanding of the quantity represented by pulses on CF, F1, and F2 outputs (watt-hour). • Billing active energy while the ADE7761A is in Case 2 must be decided knowing that the entity measured by the ADE7761A in this case is ampere-hour and not watt-hour. Users should be aware of this limitation and decide if the ADE7761A is appropriate for their application. Missing Neutral Detection The ADE7761A continuously monitors the voltage input and detects a missing neutral condition when the voltage input peak value is smaller than 9% of the analog full scale or when no zero crossings are detected on this input (see Figure 33). 0V FS FS 0V FS 9% OF FS 0V FILTER AND THRESHOLD V2 V2P V2N AGND ADC MISSING NEUTRAL |V2|PEAK < 9% OF FULL SCALE V2P –V2N V2P –V2N V2P – V2N NO ZERO CROSSING ON V2 OR Figure 33. Missing Neutral Detection The ADE7761A leaves the missing neutral mode for normal operation when both conditions are no longer valid, that is, a voltage peak value of greater than 9% of full scale and zero crossing on the voltage channel is detected (see Figure 34). FILTER AND THRESHOLD V2 V2P V2N AGND ADC MISSING NEUTRAL |V2|PEAK > 9% OF FULL SCALE AND ZERO CROSSING ON V2 FS +9% OF FS –9% OF FS V2P – V2N Figure 34. Return to Normal Mode after Missing Neutral Detection |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |