| 数据搜索系统,热门电子元器件搜索 |
|
166364 数据表(PDF) 11 Page - Eaton All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
166364 数据表(HTML) 11 Page - Eaton All Rights Reserved. |
|
11 / 36 page ![]() 10 SPD Class B, Lightning Current Arrester SPI • Field of application: For the protection of low voltage distribution systems against direct lightning stroke into the overhead power supply line or exter- nal lightning protection system (IEC 62305). • Application according to IEC 60364-5-53 Clause 534 • Test class in accordance with IEC 61643-1 • SPD-type in accordance with EN 61643-1 • Capsuled version: during the discharge process, the device does not issue any hot ionised gases. Therefore, there is no need for keeping a safety dis- tance to flammable materials. Technical Data SPI-35/440 SPI-50/NPE SPI-100/NPE Electrical Design capsuled capsuled capsuled Responding time t r < 100 ns < 100 ns < 100 ns Voltage protection level U p 1.5 kV 1.5 kV 1.5 kV Maximum continuous operating voltage U C 440 VAC 260 VAC 260 VA Temporary overvoltage test value U T (200 ms) – 1200 VAC 1200 VAC (5 s) U T = UC –– Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz Discharge current (8/20) µs I max/In 35 kA 50 kA 100 kA Impulse current I imp (10/350) µs Peak current 35 kA 50 kA 100 kA Charge Q 17.5 As 25 As 50 As Specific energy 305 kJ/ Ω 625 kJ/ Ω 2500 kJ/ Ω Insulation resistance R ISO >10 M Ω >10 M Ω >10 M Ω Follow current interrupt rating I fi 3kA r.m.s/260V 500A r.m.s/260V 100A r.m.s/260V 1.5kA r.m.s/440V – – Short-circuit current strength at max. back-up fuse 25kA r.m.s –– Maximum back-up fuse 125 AgL – – Connection diagram Mechanical Frame size 45 mm 45 mm 45 mm Device height 90 mm 90 mm 90 mm Device width 17.5 mm 17.5 mm 35 mm Weight 174 g 178 g 320 g Upper and lower lift terminal capacity rigid 0.5 - 35 mm2 0.5 - 35 mm2 10 - 50 mm2 flexible 0.5 - 25 mm2 0.5 - 25 mm2 16 - 35 mm2 Tightening torque of terminal screws 4 - 4.5 Nm 4 - 4.5 Nm 6 - 8 Nm Mounting quick fastening on DIN rail IEC/EN 60715 Degree of protection acc. to IEC 60529 (installed) IP20 (IP40) Accessories: busbars Z-GV-U/ Permitted relative air humidity < 95% Permitted ambient temperature -40°C to +85°C Dimensions (mm) SPI-35/440, SPI-50/NPE I SPI-100/NPE Installation of lightning current arresters upstream of the meter is subject to co-ordination with the relevant power supply company. Installation of an r.m.s.ective protection cascade (SPD classes B, C, D) requires co-ordinated application of the respective protective devices. This is ensured by a defined line length between protective devices. When using lightning current arresters of type SPI in connection with surge arresters SPC with a maximum continuous operating voltage Uc of 460 V AC, no specific line length or decoupling coils are required. Practical Hint Application Example Attention! SPI-.../NPE should be used only as a N-PE spark gap in a e.g. TT-system (con- nection type 2 according to IEC 60364-5- 534 Clause 534) Spark gap SPI-50/NPE SPI-100/NPE SPI-35/440 T1 SPI-50/NPE: for protection class III, IV according to IEC 62305 SPI-100/NPE: for protection class I, II, III, IV according to IEC 62305 Surge Protection SPI-35/440/3 SPI-3+1 Lightning current arrester Sets, Lightning protection classes I, II, III, IV . . .SPI-35/440 . . .SPI-100/NPE . . .SPB-D-125 . . . .Z-GV-U/3 . . .Z-GV-U/6 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |