| 数据搜索系统,热门电子元器件搜索 |
|
166364 数据表(PDF) 14 Page - Eaton All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
166364 数据表(HTML) 14 Page - Eaton All Rights Reserved. |
|
14 / 36 page ![]() SPD Class B+C, SP-B+C/ Lightning current arrester - surge arrester Sets, Lightning protection classes I, II, III, IV 13 Surge Protection • Field of application: For the protection of low voltage distribution systems against direct lightning stroke into the overhead power supply line or exter- nal lightning protection system (IEC 62305) and against indirect lightning stroke and switching operations. • Application according to IEC 60364-5-53 Clause 534 • Test class and in accordance with IEC 61643-1 • SPD-type and in accordance with EN 61643-11 • Capsuled version: during the discharge process, the device does not issue any hot ionised gases. Therefore, there is no need for keeping a safety dis- tance to flammable materials. II I Technical Data SP-B+C/3 SP-B+C/3+1 Electrical Design capsuled capsuled Responding time t r < 25 ns < 25 ns Voltage protection level U p 1.5 kV 1.5 kV Maximum continuous operating voltage U C L-(PE)N / N-PE 440 VAC / – 440 VAC / 260 VAC Temporary overvoltage test value U T L-(PE)N U T = Uc U T = Uc N-PE – 1200 VAC (200 ms) Rated frequency 50/60 Hz 50/60 Hz Discharge current (8/20) µs I max/In 3x35 kA 100 kA Impulse current I imp (10/350) µs Peak current 100 kA 100 kA Charge Q 50 As 50 As Specific energy 2500 kJ/ Ω 2500 kJ/ Ω Follow current interrupt rating I fi L-(PE)N / N-PE at 260 V 3kA rms / – 3kA rms / 100Arms at 440 V 1,5kA rms / – 1,5kA rms / – Short-circuit current strength at max. back-up fuse 25kA rms 25kA rms Maximum back-up fuse 125 AgL 125 AgL Connection diagram Mechanical Frame size 45 mm 45 mm Device height 90 mm 90 mm Device width 110 mm 164 mm Weight 1100 g 1420 g Upper and lower lift terminal capacity rigid L, N, PEN / PE 0.5 - 35 mm2 0.5 - 35 mm2 / 10 - 50 mm2 flexible L, N, PEN / PE 0.5 - 25 mm2 0.5 - 25 mm2 / 16 - 35 mm2 Tightening torque of terminal screws 4 - 4.5 Nm 4 - 4.5 Nm / 6 - 8 Nm Mounting quick fastening on DIN rail IEC/EN 60715 Degree of protection acc. to IEC 60529 (installed) IP20 (IP40) Accessories: busbars Z-GV-U/ Permitted relative air humidity < 95% Permitted ambient temperature -40°C to +70°C Dimensions (mm) Installation of lightning current arresters upstream of the meter is subject to co-ordination with the relevant power supply company. Installation of an r.m.s.ective protection cascade (SPD classes B, C, D) requires co-ordinated application of the respective protective devices. This is ensured by a defined line length between protective devices. When using lightning current arresters of type SPI in connection with surge arresters SPC with a maximum continuous operating voltage Uc of 460 V AC, no specific line length or decoupling coils are required. Practical Hint T1 T2 Lightning current arrester - surge arrester . . .SPI-35/440 . . .SPI-100/NPE for protection class I, II, III, IV . . .SPC-S-20/460/3 Lead-through terminal . . .SPB-D-125 Busbar . . .Z-GV-U/6 . . .Z-GV-U/9 . . .Z-GV-16/3P-3TE/6 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |