| 数据搜索系统,热门电子元器件搜索 |
|
166364 数据表(PDF) 12 Page - Eaton All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
166364 数据表(HTML) 12 Page - Eaton All Rights Reserved. |
|
12 / 36 page ![]() SPD Class B+C, Lightning Current Arrester - Surge Arresters SPBT12 • Field of application For the protection of low voltage distribution systems against transient overvoltage caused by direct and indirect lightning stroke and switching operations. • Application according to IEC 60364-5-53 Clause 534 • Test class , in accordance with IEC 61643-1 • SPD-type , in accordance with EN 61643-11 • Lightning protection classes III and IV in accordance with IEC 62305 • Busbars ZV-KSBI are available for all customary applications II I Technical Data SPBT12-280... SPBT12-NPE100 Electrical per pole Responding time (rate of voltage rise 5 kV/µs) < 25 ns < 100 ns Voltage protection level U p < 1.5kV < 1.5kV Voltage protection level at 5 kA (8/20) µs 950 V – Maximum continuous operating voltage U C 280 VAC 255 VAC Temporary overvoltage test value U T 370 VAC (5 s) 1200 VAC (200 ms) Rated frequency 50/60 Hz 50/60 Hz Open circuit voltage U oc 10 kV 20 kV Nominal discharge current (8/20) µs I n 25 kA 100 kA Maximum discharge current I max 50 kA 100 kA Imulse current I imp (10/350) µs Peak current 12.5 kA 100 kA Charge Q 6.25 As 50 As Specific energy 39.1 kJ/ Ω 2500 kJ/ Ω Follow current interrupt rating I fi –100 A r.m.s Maximum back-up fuse 160 AgL/gG – Maximum short-circuit current 50 kA r.m.s – Connection diagram Mechanical Frame size 45 mm 45 mm Device height 80 mm 80 mm Device width 17.5 mm 35 mm Weight 121 g 250 g Permitted ambient temperature -40°C to +70°C -40°C to +70°C Degree of protection (built-in) IP40 IP40 Upper and lower lift terminal capacity 4 - 25 mm2 4 - 35 mm2 Upper and lower open mouthed terminals for busbar thickness up to 1.5 mm 1.5 mm Tightening torque of terminal screws 2.4 - 3 Nm 2.4 - 3 Nm Quick fastening on DIN rail according to IEC/EN 60715 IEC/EN 60715 Accessories: busbars 16 mm2 Type ZV-KSBI ... Type ZV-KSBI ... Block Diagram T1 11 Surge Protection Dimensions (mm) T2 Lightning current arrester - surge arrester Sets, Lightning protection classes III, IV SPBT12-280 SPBT12-NPE100 SPBT12- 280/2 SPBT12-280/3 SPBT12-280/4 . . .SPBT12-280 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |