19 / 26 page ![]() MP5921 – 16V, 50A, 1mΩ RDS(ON), HOT-SWAP INTELLI-FUSE SOLUTION MP5921 Rev. 1.1 www.MonolithicPower.com 19 5/17/2022 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2022 MPS. All Rights Reserved. The approximate soft-start time is then 1.5ms, which is the minimum output voltage soft-start time. ON/PD Control ON/PD can be used for on/off control of the power FET and the pull-down mode of the output voltage. When ON/PD is used for on/off control, the power FET is turned on if the ON/PD voltage is higher than 1.4V. Once the ON/PD voltage is lower than 1.2V, the power FET is turned off. If ON/PD is used for VOUT pull-down mode, the ON/PD voltage must be clamped at around 1V for more than 80µs. The MP5921 recognizes 0.8V < ON/PD < 1.2V as a special state that requires VOUT to be pulled down. If ON/PD is used to turn on the power FET, there is a fixed 1.3ms insertion delay after VDD3 and VIN pass the UVLO threshold. All fault functionality is operative during the insertion delay, so the GOK signal is pulled high if no fault is detected or remains low if a fault is detected. The power FET remains off until the insertion delay time ends. At the end of the insertion delay, ON/PD behaves normally to turn on the power FET if no fault occurs. The detail logic is shown in Figure 7 when GOK is pulled up to the VDD3 voltage. VIN/ VDD33 ON/PD ON SWITCH GOK OFF >1.4 V Insertion delay Insertion delay ON Figure 7: Power FET On/Off Control when No Fault Occurs Once the ON/PD voltage is pulled above 1.4V and the insertion delay ends, the internal 12μA current source charges the power FET’s gate. Once the gate voltage reaches its threshold (VGSTH), the output voltage rises. The output voltage rises following the CLREF-controlled current limit or SS slew rate and output capacitor. If the MP5921 works in standalone mode, a capacitor on ON/PD can be used for automatic start-up by the internal 4.2µA pull-up current source. Once the ON/PD voltage reaches its turn-on threshold, the power FET gate is charged by the internal 12µA charge pump. When the ON/PD voltage is set to around 1V, the MP5921 works in pull-down mode (see Figure 8). In pull-down mode, when the power FET is turned off, an integrated 500Ω pull-down resistor attached to the output discharges the output voltage after a fixed delay time (2.1ms). If the ON/PD signal is pulled low directly, pull- down mode is disabled, and the Intelli-Fuse output voltage is discharged through the external load. ON/PD >1.4 V Around 1 V 80µs Internal PD Enable PD delay SWITCH <0.8 V 1.2 V 0.8 V FET on FET off VOUT t Figure 8: VOUT PD Mode If the MP5921 is controlled by the hot-swap controller, to achieve power FET on/off control and VOUT PD mode control, the ON/PD can be connected as shown in Figure 9. Pull ON/PD up to VDD3 through a resistor divider (RPD and RON) from the controller. If ON/PD is set to around 1V when the hot-swap controller outputs low to turn off the power FET. RPD can be calculated with Equation (4): ( ) ( ) = ON ON PD R N 4.2 μ - 1 R 2 R (4) Where N is the active parallel number. Choose RON to be 10kΩ. For example, if N is 2, then RPD can be set to around 22 kΩ. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |