| 数据搜索系统,热门电子元器件搜索 |
|
MP6605C 数据表(PDF) 11 Page - MPS Industries, Inc. |
|
|
|||||||||||||||||||||||||||||
MP6605C 数据表(HTML) 11 Page - MPS Industries, Inc. |
|
11 / 16 page ![]() MP6605C – 4-CHANNEL LOW-SIDE DRIVER WITH I2C INTERFACE MP6605C Rev. 1.0 MonolithicPower.com 11 7/11/2022 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2022 MPS. All Rights Reserved. Normal operation resumes automatically when the die temperature falls to a safe level. I2C INTERFACE The I2C interface is a two-wire, bidirectional serial interface consisting of a data line (SDA) and a clock line (SCL). The lines are pulled to a bus voltage externally when they are idle. The MP6605C interface is an I2C slave that supports a maximum clock frequency up to 400kHz. I2C Update Sequence The MP6605C requires a start command, valid I2C address, and data byte. After receiving each byte, the MP6605C acknowledges the request by pulling the SDA line low during the high period of a single clock pulse. A valid I2C address selects the MP6605C. The MP6605C performs an update on the falling edge of the LSB byte. Start and Stop Commands The start and stop commands are signaled by the master device, and they signify the beginning and the end of the I2C transfer, respectively. A start (S) command is defined as the SDA signal transitioning from high to low while SCL is high. A stop (P) command is defined as the SDA signal transitioning from low to high while SCL is high (see Figure 2). Figure 2: Start and Stop Commands Address Byte After the start command, the I2C master sends an address byte. The address byte consists of a 7-bit address field, and one bit (WR) that indicates if the transfer is a read (WR = 1) or a write (WR = 0). The four LSBs of the address are set by the A0~A3 input pins, which means that a maximum of 16 devices can be connected to the same I2C bus. The address byte is followed by an acknowledge bit (see Figure 3). S WR A 8 Bits Master to Slave Slave to Master A = Acknowledge (SDA = Low) S = Start Command P = Stop Command WR (Write = 0; Read = 1) A0 A1 A2 A3 0 1 0 Figure 3: Address Byte Data Byte After the address is acknowledged, an 8-bit data byte is sent, followed by an acknowledge bit (see Figure 4). The state of the WR bit in the address byte determines if the data is written from the master to the MP6605C, or if data is read from the MP6605C. S D0 A 8 Bits Master to Slave Slave to Master A = Acknowledge (SDA = Low) S = Start Condition P = Stop Condition D1 D2 D3 S0 x S1 S2 Slave to Master (WR = 0 (Write)) or Master to Slave (WR = 1 (Read)) Figure 4: Data Byte The D0~D3 bits can be written to or read. When they are written to 1, the corresponding output bit(s) is driven low. The S0~S2 bits are read- only, and they correspond to the state of the S0~S2 input pins. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |