| 数据搜索系统,热门电子元器件搜索 |
|
MP8042DF 数据表(PDF) 7 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP8042DF 数据表(HTML) 7 Page - Monolithic Power Systems |
|
7 / 9 page ![]() MP8042 – HIGH CURRENT, DUAL CHANNEL POWER HALF-BRIDGE INITIAL RELEASE – SPECIFICATIONS SUBJECT TO CHANGE MP8042 Rev. 0.9 www.MonolithicPower.com 7 5/23/2006 MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited. © 2006 MPS. All Rights Reserved. TM OPERATION The MP8042 is a high voltage, dual channel power half- bridge that can be configured as the output of a Class D amplifier. The output is in phase with the input, and the dead time is optimized for symmetrical performance, regardless of load conditions. The shutdown pin ( SHDN ), when set low, causes both channels 1 and 2 to be shut off. When the standby pin ( STBY ) is pulled low, it causes the outputs of both channels to go into high impedance. However, when the voltage across the BST1/2 and OUT1/2 pins drops sufficiently low, the bottom MOSFET is turned on to refresh the external bootstrap capacitor. For a bootstrap capacitor of 100nF, the refresh time is approximately 300µs. In order to prevent erratic operation, two under voltage lockout (UVLO) circuits are used. One of them is to ensure that the supply for the bottom gate drive circuit is sufficiently high and the other is for the top gate driver. Fault Protection To protect the power MOSFETs, two layers of protection are provided. The first is the current limit, wherein if the current through either the top or the bottom MOSFET exceeds an internally preset value of 5A, that particular MOSFET is immediately shut down and the complementary MOSFET is turned on. If this fails to reset the current and there is an indication that the current is going to runaway, the current foldback will kick in. This ensures that the current is reset close to zero before resuming operation. Thermal monitoring is also integrated into the MP8042. If the die temperature rises above 150 °C, both switches are turned off. The temperature must fall below 140 °C before normal operation resumes. Fault Output The MP8042 includes an open drain, active low fault indicator output ( FAULT ). A fault will be indicated if one of the following conditions is detected: the current limit is tripped, the thermal shutdown is tripped, the UVLO for the bottom gate driver is tripped or the part is disabled. A fault on any channel causes the FAULT pin to be pulled low. However, only that fault channel has its output set to high impedance. Do not apply more than 6V to the FAULT pin. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |