| 数据搜索系统,热门电子元器件搜索 |
|
LTC2609IGN 数据表(PDF) 15 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC2609IGN 数据表(HTML) 15 Page - Linear Technology |
|
15 / 20 page ![]() 15 LTC2609/LTC2619/LTC2629 26091929f OPERATIO C3 1ST DATA BYTE Input Word (LTC2609) Write Word Protocol for LTC2609/LTC2619/LTC1629 C2 C1 C0 A3 D13 D14 D15 S WA SLAVE ADDRESS 1ST DATA BYTE D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 A 2ND DATA BYTE A 3RD DATA BYTE A P 2609 F03 2ND DATA BYTE INPUT WORD 3RD DATA BYTE C3 1ST DATA BYTE Input Word (LTC2619) C2 C1 C0 A3 D11 D12 D13 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 X X 2ND DATA BYTE 3RD DATA BYTE C3 1ST DATA BYTE Input Word (LTC2629) C2 C1 C0 A3 A2 A2 A2 A1 A1 A1 A0 A0 A0 D9 D10 D11 D8 D7 D6 D5 D4 D3 D2 D1 D0 X X X X 2ND DATA BYTE 3RD DATA BYTE loads a 16-bit data word from the 32-bit shift register into the input register of the selected DAC, n. An update operation copies the data word from the input register to the DAC register. Once copied into the DAC register, the data word becomes the active 16-, 14- or 12-bit input code, and is converted to an analog voltage at the DAC output. The update operation also powers up the selected DAC if it had been in power-down mode. The data path and registers are shown in the Block Diagram. Figure 3 Power-Down Mode For power-constrained applications, power-down mode can be used to reduce the supply current whenever less than four outputs are needed. When in power-down, the buffer amplifiers, bias circuits and reference inputs are disabled, and draw essentially zero current. The DAC outputs are put into a high impedance state, and the output pins are passively pulled to REFLO through individual 90k resistors. Input- and DAC-register contents are not disturbed during power down. Any channel or combination of channels can be put into power-down mode by using command 0100b in combination with the appropriate DAC address, (n). The 16-bit data word is ignored. The supply current is reduced by approximately 1/4 for each DAC powered down. The effective resistance at REFx (Pins 3, 6, 12 and 15) are at high impedance (typically > 1G Ω) when the corre- sponding DACs are powered down. Normal operation can be resumed by executing any command which includes a DAC update, as shown in Table 2. The selected DAC is powered up as its voltage output is updated. When a DAC which is in a powered-down state is powered up and updated, normal settling is delayed. If less than four DACs are in a powered-down state prior to the update command, the power-up delay time is 5 µs. If on the other hand, all four DACs are powered down, Table 2 COMMAND* C3 C2 C1 C0 0000 Write to Input Register n 0001 Update (Power Up) DAC Register n 0010 Write to Input Register n, Update (Power Up) All n 0011 Write to and Update (Power Up) n 0100 Power Down n 1111 No Operation ADDRESS (n)* A3 A2 A1 A0 0000 DAC A 0001 DAC B 0010 DAC C 0011 DAC D 1111 All DACs *Command and address codes not shown are reserved and should not be used. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |