8 / 14 page ![]() E5AX-P E5AX-P 8 Inputting Parameters The Temperature Controller has three display levels, 0, 1, and 2, in which only specific parameters can be set. Level 0 is the initial and is auto- matically entered at power application. To change the mode to set or change a different group of parameters, hold down the Level Key for 2 seconds minimum. The display level mode changes as shown below. Actual displays vary with models and switch settings. If a display does not appear as expected, check your switch settings. Level 0 Power ON Level 1 Level 2 Press the Level Key. Press the Level Key. Press the Level Key. Valve travel, main set- ting, alarm set value, input shift, PID con- stants Lower/upper setting limit, alarm hysteresis, disable band, motor calibration, Fully open/close position, Fully open/close time Input type, alarm mode Level 0 Process value m 0 Process value 0 Press a. a 0 al 0 in–5 0 p 40.0 i 240 d 40 Press a. Press a. Press a. Press a. Press a. Press a. Press a. Valve travel Main setting Valve travel Alarm value Input shift Proportional band Integral time Derivative time (Note 1) (Note 2) (Note 3) (Note 4) (Note 5) (Note 5) (Note 5) Process value PV SV Note: 1. Not displayed in automatic output mode. “m––– ” will be displayed if a potentiometer is not connected. 2. Not displayed in manual output mode. “a––– ” will be dis- played if a potentiometer is not connected. 3. Not displayed when the alarm is disabled (SW203 set to 0 or 9). 4. Not displayed when the input shift display is disabled (SW201, pin 3 OFF). 5. Not displayed when PID display is disabled (SW201, pin 6 OFF). Main Setting The set point can be changed with the Up and Down Keys. Valve Travel The value travel can be monitored. If a potentiometer is not con- nected, the display will show “a––– ” for automatic and “m––– ” for manual operation. While “m ” is displayed in manual output mode, the Up Key will turn ON the OPEN output and the Down Key will turn ON the CLOSE output. Selecting the Output Mode The A/M Key can be pressed for one second or longer to change between the automatic and manual output modes. The balance- less-bumpless function will operate to prevent the output from changing abruptly. Automatic Output Mode In automatic output mode, the control will function automatically. When the A/M Key is pressed and the automatic output mode is first entered, displays like the following will appear (display level 0). 123 80 PV SV Process value Main setting Manual Output Mode In manual output mode, the controller can be operated with the Up and Down Keys. The Up Key will turn the OPEN output ON and light the OPEN indicator. The Down Key will turn ON the CLOSE output and light the CLOSE indicator. When the A/M Key is pressed and the manual output mode is first entered, displays like the following will appear (display level 0). 123 m 80 PV SV Process value Valve position (%) The MANU indicator will light and remain lit until the automatic out- put mode is returned to. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |