3 / 14 page ![]() E5AX-P E5AX-P 3 Characteristics Setting accuracy (+0.3% of set value or +1%C, whichever greater), +1 digit max. Indication accuracy (+0.3% of set value or +1%C, whichever greater), +1 digit max. (Set value coincides with the indicated value, because no relative error exists between both values.) Disable band 0.1% to 10.0% (in units of 0.1%) Proportional band 0.1% to 999.9 %C/%F (in units of 0.1%C/%F) Integral time 1 to 3,999 s (in units of 1 s) Derivative time 0 to 3,999 s (in units of 1 s) Alarm output setting range Thermocouple: –999% to 9,999%C/%F (in units of 1%C/%F) Platinum resistance thermometer: –99.9% to 999.9%C/%F (in units of 0.1%C/%F) Alarm output hysteresis 0.0% to 999.9 %C/%F (in units of 0.1%C/%F) Sampling period 500 ms (temperature sensor input) Output refresh period 500 ms Display refresh period 500 ms (temperature sensor input) Valve travel indication –99% to 999% (in units of 1%) Full Open/close time 1 to 999 s ( in units of 1 s) Input shift Thermocouple: –999% to 9,999%C/%F (in units of 1%C/%F) Platinum resistance thermometer: –99.9% to 999.9%C/%F (in units of 0.1%C/%F) Insulation resistance 20 MW min. (at 500 VDC) Dielectric strength 2,000 VAC 50/60 Hz for 1 min between terminals of different polarities Vibration resistance Malfunction: 2 to 55 Hz, 2G 10 min each in X, Y, and Z directions Destruction: 10 to 55 Hz, 0.75-mm double amplitude 2 hrs each in X, Y, and Z directions Shock resistance Malfunction: 200 m/s2 3 times each in 6 directions Destruction: 300 m/s2 3 times each in 6 directions Life expectancy Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min. Ambient temperature Operating: –10% to 55%C (with no icing) Storage: –25% to 65%C (with no icing) Ambient humidity Operating: 35% to 85% Memory protection Non-volatile memory Enclosure ratings Front panel: IEC standard IP50 Rear case: IEC standard IP20 Terminals: IEC standard IP00 Weight Standard: Approx. 350 g; Communications: Approx. 480 g; Mounting bracket: Approx. 50 g *The accuracy of U thermocouples under temperatures from –150% to 400%C (–240% to 700%F) is +2%C (+3.6%F) +1 digit. Accuracy is reduced below –150%C (–240%F). The accuracy of R and S thermocouples under 0% to 200%C (0% to 400%F) is +3%C (+5.4%F) +1 digit. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |