| 数据搜索系统,热门电子元器件搜索 |
|
E5AX-PRR03 数据表(PDF) 11 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5AX-PRR03 数据表(HTML) 11 Page - Omron Electronics LLC |
|
11 / 14 page ![]() E5AX-P E5AX-P 11 Starting Control Operation The E5AX will start control operations as soon as power is turned on until power is turned off. If you don’t want control operations to be performed while setting parameters, turn off the power and then turn it back on after setting the desired parameters. Auto-tuning When the Level Key and Mode Key are pressed at the same time for 1 second minimum, the Temperature Controller automatically starts tuning the PID constants. While auto-tuning is in operation, the au- to-tuning indicator on the front panel will flash. The Temperature Controller executes control based on the set PID constants (factory set to P = 40%C, I = 240 seconds, and D = 40 seconds) until the tem- perature of the controlled system reaches the set temperature. After that, the Temperature Controller automatically adjusts the PID con- stants using the limit cycle method. When the auto-tuning indicator turns off, the auto-tuning is terminated and PID constants are re- newed. Main setting Previous PID constants New PID constants AT indicator flashes Limit Cycle Method: the optimum PID constants are calculated by this method by varing the control output variable and generating ex- ternal oscillation. Auto-tuning can be carried out regardless of whether the Tempera- ture Controller is performing reverse (heating) or normal (cooling) operation. To stop auto-tuning, hold down the Level Key and Mode Key again simultaneously for 1 second minimum. All settings will re- turn to those prior to the beginning of auto-tuning. Automatic tuning can be executed at any time: at power application, while the temper- ature is rising, or after the control action has stabilized. Error Messages The Temperature Controller is provided with self-diagnostic functions, and will display an error message on the PV display when an error is detected. Message Cause Control output Alarm output Normal Reverse ffff Input temperature has exceeded the upper limit of the temperature range by more than 20%C. Open: OFF Close: ON Open: ON Close: OFF Sends alarm signal in ac- cordance with the set alarm mode. –––– Input temperature has fallen below the lower limit of the temperature range by more than 20%C.* Open: ON Close: OFF Open: OFF Close: ON Sends alarm signal in ac- cordance with the set alarm mode. 5.err (flashes) The thermocouple has burned out or short-circuit bar has been removed. The plati- num resistance thermometer has burned out or A and B terminals have been short-cir- cuited. Open: OFF Close: ON Open: ON Close: OFF Sends alarm signal in ac- cordance with the set alarm mode. Proportional alarm output is OFF, how- ever. e111 (flashes) e333 (flashes) Memory failure (e111) or A/D converter failure (e333) has occurred. Temperature Controller must be repaired if recovery is not made by turning power off once and on again. Open: OFF Close: OFF Open: OFF Close: OFF OFF *When the temperature resistance thermometer is used, this message is displayed when the temperature has fallen below -99.9%C. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |