7 / 12 page ![]() E5CS-X E5CS-X 7 Temperature Indication Switching Key If the set temperature is shifted out- side the temperature range as a re- sult of changing the range, the set temperature is displayed. It is then automatically changed to the maxi- mum or minimum vale of the newly set range. If the alarm value is shifted outside the temperature range as a result of changing the range, it is automati- cally changed to the maximum value of the newly set range. If the alarm mode selector switch is set to “0” or “9”, no alarm value is displayed. On models without alarms, no alarm value is displayed. DIP Switch Settings The control mode and other settings are selected using the internal DIP switch as shown below. ON 16 5 4 3 2 PX ON Function P X 1 2 3 4 5 6 Protect ON OFF --- Not used Control mode PID ON mode ON/OFF OFF Proportional period 2 s ON period 20 s OFF Control output Normal ON output Reverse OFF Input shift Setting enabled ON Setting disabled OFF Temperature sensor DIN ON sensor standard JIS OFF Scale indicator °F ON indicator (selectable) °C OFF Setting the Alarm Mode The desired alarm mode can be chosen from one of the eight alarm modes using the alarm mode selector switch as shown below. Switch setting Mode Alarm output 0, 9 No alarm function OFF 1 Upper- and lower-limit alarms 2 Upper-limit alarm 3 Lower-limit alarm 4 Upper- and lower-limit range alarm 5 Upper- and lower-limit alarms with standby sequence (see note) 6 Upper-limit alarm with standby sequence (see note) 7 Lower-limit alarm with standby sequence (see note) 8 Absolute-value alarm Note: The selector switch is factory-set to “2.” The triangular mark Y indicates the set temperature. X denotes alarm values. Y denotes the set value value within the temperature range. Operation of Standby Sequence Alarm output set with standby sequence will operate in the way shown below when the temperature rises above the upper-limit. Alarm output set with standby sequence will operate in the way shown below when the temperature drops below the upper-limit. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |