6 / 12 page ![]() E5CS-X E5CS-X 6 Operation Temperature Setting Press the temperature indication switching key until the SP indicator lights. Then set the desired temperature value using the upward and downward setting keys. Alarm Setting Press the temperature indication switching key until the AL indicator lights. Then set the desired alarm value in units of °C or °F. If the present temperature reaches the set alarm value, alarm output will be enabled. Sensor Failure The error message “FFF” or “– – –” will appear on the main display if the temperature sensor, such as the thermocouple or platinum re- sistance thermometer, short-circuits or breaks. (Refer to Error Mes - sages for details of the messages displayed.) Note: Neither the set alarm value is displayed nor the AL indicator lights with the internal alarm mode selector switch set to 0 or 9. The alarm mode selector switch is provided inside the housing, and is positioned differently on each model. Function Setting The various functions of the Temperature Controller are set using the switches on the internal mechanism. To gain access to these switches, the internal mechanism must be first drawn out from the housing. Push the tab on the underside of the housing, and pull out the mechanism. Select the desired temperature range using the temperature range selector switch (rotary DIP type). Eight or nine temperature ranges can be selected depending on the model. The set temperature is automatically changed when the tempera- ture range is changed. Be sure to confirm the set temperature. Temperature range selector switch Alarm mode selector switch Right side view Temperature unit (C ° or F°), where a choice is available, is selected using pin 6 of the internal DIP switch which is also used for other set- tings, such as the control mode and sensor compensation. Internal DIP switch Left side view The procedures for making actual settings are given below. Setting the Temperature Range Set the desired temperature range by using the temperature range selector switch (“Set no.” setting in the tables below). Eight or nine temperature ranges can be selected depending on the model. Thermocouple Type The display can indicate temperatures 10% beyond each of the set ranges. Platinum Resistance Thermometer Type Do not set the selector switch to “9.” Doing so will result in the error message “FFF” or “– – –” being displayed. Note: 1. The unit in which the temperature can be set is multiplied by 10 when the temperature range is changed from 0.0 to 50.0 or 0.0 to 99.9 to a range in which the temperature can be set in 1 ° units. Conversely, if the temperature range is changed from one in which the temperature can be set in 1 ° units to a range of 0.0 to 50.0 or 0.0 to 99.9, the unit is decreased to 1/10 of the original unit. 2. The display can indicate temperatures 10% beyond each of the set ranges. Thermistor Type Note: 1. The temperature range selector switch is factory-set to “0.” With a temperature range, such as 50 ° to 150°C, that exceeds the setting range, the indication unit is au- tomatically adjusted to the minimum value. The set tem- perature is displayed when power is turned ON. 2. The temperature range that can actually be indicated for a set temperature range of –50 ° to 50°C is –50° to 60°C. For other temperature range settings it is the full scale ±10%. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |