9 / 18 page ![]() www.sensirion.com / D1 Version 1 – June 2025 9 / 18 3.4.1 start_continuous_measurement The start_continuous_measurement command will start a continuous measurement. Command Command Hex Code Argument Read Data Execution Time (ms) Description start_continu ous_measure ment 0x218B - - - Starts continuous measurement with 1 s sampling interval. Recommended operation sequence: 1. Send the start_continuous_measurement command. 2. Wait 1 s13. 3. Send the read_measurement command (Section 3.4.3) and wait the specified execution time. 4. Read out the measurement data. 4.1. If data is not yet available, wait 150 ms and retry to read out the measurement data. 5. Wait 1 s13. 6. Repeat steps 3-5 as needed. 7. To stop the continuous measurement, send the stop_continuous_measurement command (Section 3.4.2) and wait the specified execution time. 3.4.2 stop_continuous_measurement The stop_continuous_measurement command will finish the currently running measurement before returning to idle mode. During the execution time, the sensor will not acknowledge its I2C address nor accept commands. Command Command Hex Code Argument Read Data Execution Time (ms) Description stop_continuo us_measurem ent 0x3F86 - - 1’200 Stops the continuous measurement and put the sensor into idle mode. 3.4.3 Read_measurement Measurement data is read out through the read_measurement command. The measurement data buffer is emptied upon read-out. Subsequent measurement data can be readout by sending the sensor’s I2C address and the read direction bit. The sensor will respond with a NACK if no measurement data is available. The I2C master can abort the read transfer with a NACK followed by a STOP condition after any data byte. See Section 3.5 for the signal output and input conversion. The sensor status is used to determine if the sensor is in testing mode (See Section 3.4.13). Command Command Hex Code Argument Read Data Execution Time (ms) Description read_measur ement 0xEC05 - Byte0: CO2 concentration 8msb Byte1: CO2 concentration 8lsb Byte2: CRC Byte3: Temperature 8msb Byte4: Temperature 8lsb Byte5: CRC Byte6: Relative Humidity 8msb Byte7: Relative Humidity 8lsb Byte8: CRC Byte9: Sensor Status 8msb Byte10: Sensor Status 8lsb Byte11: CRC 1 Reads out the measurement data. Values for temperature and humidity are provided as received from the external temperature and humidity sensor. 13 Note that the sensor and the microcontroller are subject to clock tolerances. The effective sampling interval is 1’000 ms ± 150 ms. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |