| 数据搜索系统,热门电子元器件搜索 |
|
STCC4-D-R3 数据表(PDF) 13 Page - Sensirion AG Switzerland |
|
|
|||||||||||||||||||||||||||||
STCC4-D-R3 数据表(HTML) 13 Page - Sensirion AG Switzerland |
|
13 / 18 page ![]() www.sensirion.com / D1 Version 1 – June 2025 13 / 18 3.4.14 disable_testing_mode The disable_testing_mode command is used to exit the testing mode. The sensor is not in testing mode when the 2nd most significant bit of Byte 10 from the read_measurement (Section 3.4.3) output is equal to 0. Command Command Hex Code Argument Consecutive Read Execution Time (ms) Description disable_testi ng_mode 0x3F3D - - - Disables the testing mode. 3.4.15 perform_forced_recalibration The perform_forced_recalibration command (FRC) is used to correct the sensor’s CO2 concentration output with an externally provided target CO2 concentration. Ensure the sensor reading and environmental conditions, including CO2 concentration, are stable for the duration of the recommended operation sequence. See Section 3.5 for the signal output and input conversion. Accepted input values are between 0 – 32’000 ppm. Command Command Hex Code Argument Consecutive Read Execution Time (ms) Description perform_for ced_recalibr ation 0x362F Byte0: Target CO2 concentration 8msb Byte1: Target CO2 concentration 8lsb Byte2: CRC Byte0: CO2 concentration correction 8msb Byte1: CO2 concentration correction 8lsb Byte2: CRC 90 Performs FRC to the target CO2 concentration. Failed command execution will return 0xFFFF. Recommended operation sequence: 1. Operate the sensor for a minimum of 30 s in continuous mode or 30 single shot measurements, corresponding to 5 minutes in single shot measurement mode with a 10 s sampling interval. For sampling intervals higher than 10 s, increase the operation time accordingly. 2. If operating in continuous mode, send the stop_continuous_measurement command (Section 3.4.2) and wait for the specified execution time. Else if operating in single shot mode, the sensor must remain in idle mode, i.e., must not be sent to sleep mode, after operation. 3. Send the perform_forced_recalibration command with the target CO2 concentration and optionally read out the applied FRC correction. 3.4.16 get_product_id The get_product_ID command can be used to identify the sensor and verify the communication. Command Command Hex Code Argument Consecutive Read Execution Time (ms) Description Get_product _id 0x365B - 6 x (2 Bytes + 1 CRC) 1 Returns a 32-bit product ID and 64-bit unique serial number. Product Product ID STCC4 0x0901018A |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |