10 / 18 page ![]() www.sensirion.com / D1 Version 1 – June 2025 10 / 18 3.4.4 set_rht_compensation External relative humidity (RH) and temperature (T) compensation values can be written through the set_rht_compensation command when the SHT4x is not controlled by STCC4 through the dedicated I2C controller interface (see Section 2.5). The RH and T values must be provided from the same RHT sensor. The written RHT values are utilized for RHT compensation after a maximum of one measurement interval. The default or last written values are used for RHT compensation until overwritten. Power cycling resets the values to the default values of 25 °C and 50 %RH. See Section 3.5 for the signal output and input conversion. Do not use the set_rht_compensation command when an SHT4x is controlled by STCC4 through the I2C controller interface. Command Command Hex Code Argument Consecutive Read Execution Time (ms) Description set_rht_com pensation 0xE000 Byte0: Temperature 8msb Byte1: Temperature 8lsb Byte2: CRC Byte3: Relative humidity 8msb Byte4: Relative humidity 8lsb Byte5: CRC - 1 Writes the RHT values for compensation. Example for 25 °C and 50 %RH: [0xE0, 0x00, 0x66, 0x66, 0x93, 0x72 0xB0, 0xDC] 3.4.5 set_pressure_compensation External pressure values can be written through the set_pressure_compensation command. The written pressure value is applied for pressure compensation after a maximum of one measurement interval. The default or the last written value is used in pressure compensation until overwritten. Power cycling resets the sensor to the default value of 101’300 Pa. See Section 3.5 for the signal output and input conversion. Input values are clipped to a range between 40’000 – 110’000 Pa. Command Command Hex Code Argument Consecutive Read Execution Time (ms) Description set_pressure _compensat oin 0xE016 Byte0: Pressure 8msb Byte1: Pressure 8lsb Byte2: CRC - 1 Writes the pressure value. Example for 101’300 Pa: [0xE0, 0x16, 0xC5, 0xDA, 0x83] 3.4.6 measure_single_shot The measure_single_shot command conducts an on-demand measurement of CO2 gas concentration. Command Command Hex Code Argument Consecutive Read Execution Time (ms) Description measure_sin gle_shot 0x219D - - 500 Performs a single shot measurement. Recommended operation sequence: 1. Wake the sensor up from sleep mode to idle mode with the exit_sleep_mode command (Section 3.4.8). 2. Send the measure_single_shot command and wait for the specified execution time. 3. Send the read_measurement command (Section 3.4.3) and wait for the specified execution time. 4. Read out the measurement data. 5. Set the sensor to sleep mode with the enter_sleep_mode command (Section 3.4.7). 6. Wait before the next measurement. A sampling interval between 5 s and 600 s (10 minutes) is recommended to ensure proper operation of the ASC algorithm. 7. Repeat steps 1-5 as required by the application. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |