| 数据搜索系统,热门电子元器件搜索 |
|
BQ30Z554DBT-R1.B 数据表(PDF) 20 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
BQ30Z554DBT-R1.B 数据表(HTML) 20 Page - Texas Instruments |
|
20 / 32 page ![]() bq30z554-R1 SLUSBD4 – OCTOBER 2013 www.ti.com Authentication • The bq30z554-R1 supports authentication by the host using SHA-1. • SHA-1 authentication by the gas gauge is required for unsealing and full access. Power Modes The bq30z554-R1 supports five power modes to reduce power consumption: • In NORMAL mode, the bq30z554-R1 performs measurements, calculations, protection decisions, and data updates in 0.25-s intervals. Between these intervals, the bq30z554-R1 is in a reduced power stage. In addition, the device will provide information for peak TURBO mode power operation. • The bq30z554-R1 supports a TURBO mode operation by providing information to the host MCU about the battery pack's ability to deliver peak power. The method of operation is based on the host MCU reading register 0x59 (TURBO_POWER) to determine if the selected power level for TURBO mode operation of the MCU is below the max power reported by the gas gauge. Additionally, the device reports current information during the power pulse by reading register 0x5E (TURBO_CURRENT). The information reported by these two registers allows the MCU to determine if the selected TURBO mode operation is safe and will not cause any system reset due to transient power pulses. • In SLEEP mode, the bq30z554-R1 performs measurements, calculations, protection decisions, and data updates in adjustable time intervals. Between these intervals, the bq30z554-R1 is in a reduced power stage. The bq30z554-R1 has a wake function that enables exit from SLEEP mode when current flow or failure is detected. • In SHUTDOWN mode, the bq30z554-R1 is completely disabled. • In SHIP mode, the bq30z554-R1 enters a low-power mode with no voltage, current, and temperature measurements, the FETs are turned off, and the MCU is in a halt state. The device wakes up upon SMBus communication detection. NOTE For a detailed description of the SBS Commands and Data Flash (DF) Registers, refer to the bq30z554-R1 Technical Reference Manual (SLUUA79). Configuration System Present Operation The bq30z554-R1 checks the PRES pin periodically (1 s). If PRES input is pulled to ground by the external system, the bq30z554-R1 detects this as system present. Battery Power Interrupt Operation The bq30z554-R1 can interrupt the battery power by using an external push-button switch and detecting a low- level threshold signal on the GPIO terminal (pin should be configured with an internal pull-up). Once the push button is pressed, there is a delay of 1 s (default) for debounce to detect the low-level threshold. There is also a data flash command for the battery power interrupt timeout. The default value is 30 minutes. If the push-button switch is selected before this timeout, the battery power is restored based on this action. Timeout Configuration The timeout feature allows the battery power to be restored once the timer expires. Alternatively, if the value is set to 0, this feature is disabled. Subclass Class Subclass Offset Name Type Min Max Default Unit ID Power 248 Power Off 0 Timeout U2 0 65535 30 min 20 Submit Documentation Feedback Copyright © 2013, Texas Instruments Incorporated Product Folder Links :bq30z554-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |