| 数据搜索系统,热门电子元器件搜索 |
|
PCF8563TS/4 数据表(PDF) 7 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCF8563TS/4 数据表(HTML) 7 Page - NXP Semiconductors |
|
7 / 45 page ![]() PCF8563 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2015. All rights reserved. Product data sheet Rev. 11 — 26 October 2015 7 of 45 NXP Semiconductors PCF8563 Real-time clock/calendar 8.3 Control registers 8.3.1 Register Control_status_1 [1] Default value. [2] Bits labeled as N should always be written with logic 0. 8.3.2 Register Control_status_2 Alarm registers 09h Minute_alarm AE_M MINUTE_ALARM (0 to 59) 0Ah Hour_alarm AE_H x HOUR_ALARM (0 to 23) 0Bh Day_alarm AE_D x DAY_ALARM (1 to 31) 0Ch Weekday_alarm AE_W xxxxWEEKDAY_ALARM (0 to 6) CLKOUT control register 0Dh CLKOUT_control FE xxxxxFD[1:0] Timer registers 0Eh Timer_control TE xxxxxTD[1:0] 0Fh Timer TIMER[7:0] Table 4. Formatted registers overview …continued Bit positions labelled as x are not relevant. Bit positions labelled with N should always be written with logic 0; if read they could be either logic 0 or logic 1. After reset, all registers are set according to Table 27. Address Register name Bit 7 6 5 4 3 2 1 0 Table 5. Control_status_1 - control and status register 1 (address 00h) bit description Bit Symbol Value Description Reference 7 TEST1 0[1] normal mode must be set to logic 0 during normal operations Section 8.9 1 EXT_CLK test mode 6N 0[2] unused 5STOP 0[1] RTC source clock runs Section 8.10 1 all RTC divider chain flip-flops are asynchronously set to logic 0; the RTC clock is stopped (CLKOUT at 32.768 kHz is still available) 4N 0[2] unused 3 TESTC 0 Power-On Reset (POR) override facility is disabled; set to logic 0 for normal operation Section 8.11.1 1[1] Power-On Reset (POR) override may be enabled 2to0 N 000[2] unused Table 6. Control_status_2 - control and status register 2 (address 01h) bit description Bit Symbol Value Description Reference 7to5 N 000[1] unused 4TI_TP 0[2] INT is active when TF is active (subject to the status of TIE) Section 8.3.2.1 and Section 8.8 1INT pulses active according to Table 7 (subject to the status of TIE); Remark: note that if AF and AIE are active then INT will be permanently active |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |