135 / 139 page ![]() 135/139 15 IMPORTANT NOTES Refer to Table 32 which provides a list of the trace codes for each of the recent silicon revisions. Silicon revisions are identifiable: – on the device package, by the last letter of the Trace Code marked on the device package. – on the box, by the last 3 digits of the Internal Sales Type printed in the box label. See also Figure 92. on page 137 Table 32. Device Identification 15.1 A/ D CONVERTER ACCURACY FOR FIRST CONVERSION Description When the ADC is enabled after being powered down (for example when waking up from HALT, ACTIVE-HALT or setting the ADON bit in the AD- CCSR register), the first conversion (8-bit or 10- bit) accuracy does not meet the accuracy specified in the datasheet. Workaround In order to have the accuracy specified in the da- tasheet, the first conversion after a ADC switch-on has to be ignored. Note: This limitation does not apply to Flash silicon rev. G devices (see Table 32). 15.2 A/D CONVERTER CONVERSION SPEED Description Following a change in the fabrication location, the typical ADC conversion speed value for Flash de- vices has improved from a previous value of 28µs to 4µs. When migrating software from Rev X to Rev G de- vices (refer to Table 32) care should be taken when using ADC interrupts. Workaround Firstly, on Rev G devices, only the use of One- Shot conversion mode is recommended in con- nection with ADC interrupts. In Continuous Conversion mode, to avoid getting trapped in a continuous interrupt, the ADC inter- rupt routine must always have sufficient time to ex- ecute completely before the next ADC conversion interrupt, especially if the ADC interrupt is disabled outside of this routine. With the shorter conversion speed value, the interrupt may not be serviced fast enough. For this reason, on Rev G devices, the Continuous Conversion mode is not recommend- ed in connection with ADC interrupts. Secondly, in the interests of keeping code portable between all Flash/ROM versions, using the ADC as a source of a delayed trigger event is not ad- vised. However, in such a scenario, a delay loop should be inserted for Rev G Flash devices to en- sure that the timing remains the same for any such ADC delayed trigger events. Device Type (Silicon Rev.) Trace Code marked on device/ Internal Sales Type on box label Flash Devices (Rev G) (Latest Flash silicon) “xxxxxxxxxG” / 72F62xxxxx$x4 Flash Devices (Rev X) (Previous Flash silicon) “xxxxxxxxxX” / 72F62xxxxx$x8 “xxxxxxxxxX” / 72F62xxxxx$x9 ROM Devices (Rev Z) “xxxxxxxxxZ” / 7262xxxxx$x2 “xxxxxxxxxZ” / 7262xxxxx$x3 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |