| 数据搜索系统,热门电子元器件搜索 |
|
STDRIVE101 数据表(PDF) 22 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STDRIVE101 数据表(HTML) 22 Page - STMicroelectronics |
|
22 / 32 page ![]() • GHSx output is high and (VS - VOUTx) > VDSth for more than tDFSC Important: The VDS monitoring is implemented assuming that the supply of the power stage (VM) is at the same voltage of the STDRIVE101 supply (VS). Supplying the power stage with a voltage VM lower than VS the VDS monitoring protection could not work properly. In particular, if the voltage difference 'VS - VM' is greater than VDSth, the protection will be triggered each time the high-side is turned on, regardless of the current flowing in the MOSFET. For this reason it is recommended, when using the VDS monitoring protection to supply the STDRIVE101 (VS) and the power stage (VM) at the same voltage. In case it is required to use a VM voltage lower than VS, the VDS monitoring protection must be disabled setting the SCREF pin above the VSCREF,dis voltage. As soon as the protection is triggered, all the gate drivers outputs are forced low, the nFAULT output is forced low and the protection is latched. In this condition all the gate driver outputs are kept low whatever the driving inputs (refer to Figure 6). The protection is released only when the device enters standby mode. Note: SCREF pins structure does not allow a bias without VS supply voltage. 5.7 Overcurrent comparator The STDRIVE101 embeds a comparator suitable for overcurrent detection of the power stage through a shunt resistor. When the input voltage at CP pin is higher than internal reference voltage (VREF), the device enters into a protection state: all the gate driver outputs are forced low and the nFAULT open drain output is forced low. The device automatically leaves the protection state after a tDISABLE time (refer to Figure 5 for details). 5.8 Thermal protection The device embeds an overtemperature shutdown protection through thermal sensor placed next to the linear regulator block. When the overtemperature protection occurs, the linear regulator is switched off and the nFAULT output is forced low. The thermal shutdown condition expires when the temperature goes below the “TSD- TSDhys” temperature (auto-restart). Figure 19. Thermal shutdown management V nFAULT T j T jSD Thermal shutdown T jSD,hyst Power stage ENABLED ENABLED DISABLED STDRIVE101 Overcurrent comparator DS13472 - Rev 1 page 22/32 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |