| 数据搜索系统,热门电子元器件搜索 |
|
AMC7832IPAP 数据表(PDF) 4 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
AMC7832IPAP 数据表(HTML) 4 Page - Texas Instruments |
|
4 / 74 page ![]() AMC7832 SLAS836 – MARCH 2014 www.ti.com Terminal Functions TERMINAL DESCRIPTION NUMBER NAME Digital ground. Ground reference point for all digital circuitry on the device. Ideally, AGND and DGND should be at the 1 DGND same potential (GND) and must not differ by more than ±0.3-V. 2 DVDD Digital supply voltage. (+4.5-V to +5.5-V). Must be the same value as AVDD. 3 IOVDD IO supply voltage. (+1.8-V to +5.5-V). Sets the IO operating voltage and threshold levels. Must not exceed DVDD. 4 RESET Reset input, active low. Logic low on this terminal causes the device to perform a hardware reset. Serial interface data output. The SDO terminal is in high impedance when CS is high. Data is clocked out of the input 5 SDO shift register on each falling edge of SCLK. 6 SDI Serial interface data input. Data is clocked into the input shift register on each rising edge of SCLK. 7 SCLK Serial interface clock. Active low serial data enable. This input is the frame synchronization signal for the serial data. When this signal goes 8 CS low, it enables the input shift register. General purpose digital I/O 0 (default). This terminal is a bidirectional open-drain, digital input/output with internal 48- 9 GPIO0/ALARMIN k Ω pull-up resistor to IOVDD. Alternatively the terminal can be set to operate as ALARMIN, an alarm control signal, digital input, active low. General purpose digital I/O 1 (default). This terminal is a bidirectional open-drain, digital input/output with internal 48- 10 GPIO1/ ALARMOUT k Ω pull-up resistor to IOVDD. Alternatively the terminal can be set to operate as ALARMOUT, a global alarm. Open drain output. This terminal goes low (active) when an alarm event is detected. General purpose digital I/O 2 (default). This terminal is a bidirectional open-drain, digital input/output with internal 48- 11 GPIO2/ADCTRIG k Ω pull-up resistor to IOVDD. Alternatively the terminal can be set to operate as ADCTRIG, an external conversion trigger, active low. The falling edge starts the sampling and conversion of the ADC. General purpose digital I/O 3 (default). This terminal is a bidirectional open-drain, digital input/output with internal 48- k Ω pull-up resistor to IOVDD. Alternatively the terminal can be set to operate as DAV, Data available indicator, active 12 GPIO3/DAV low output. In direct mode, the DAV terminal goes low (active) when the conversion ends. In auto mode, a 1µs pulse (active low) appears on this terminal when a conversion cycle finishes. DAV stays high when deactivated. 13 GPIO-4 14 GPIO-5 General purpose digital I/O. This terminal is a bidirectional open-drain, digital input/output with internal 48-k Ω pull-up resistor to IOVDD. 15 GPIO-6 16 GPIO-7 Lowest potential in the system. Typically tied to -12-V but if all DACs are set in a positive output range it should be 17 AVEE connected to AGND. DAC_A11, DAC_A10, 18,19, 22, 24 DAC group A. These channels share the same range and clamp voltage. DAC_A9, DAC_A8 Negative analog supply for DAC group A. Sets the power-on-reset and clamp voltage values. Typically tied to AVEE 20 AVSSA when the DAC range for group A is set to -10 to 0-V or AGND for the positive output ranges. This terminal determines the DAC range for DAC group A. If tied to AGND the DAC range is 0 to +5-V or 0 to+10-V. 21 VRANGEA Otherwise if tied to +2.5-V (can be tied to REF_OUT terminals) the DAC range is -10 to 0-V. Analog ground. Ground reference point for all analog circuitry on the device, AGND. Connect AGND1, AGND2 and 23 AGND1 AGND3 to the same potential, AGND. 25 AVCC_AB Positive analog power for DAC groups A and B. Must be tied to AVCC_CD. This terminal determines the DAC range for DAC group B. If tied to AGND the DAC range is 0 to +5-V or 0 to +10-V. 26 VRANGEB Otherwise if tied to +2.5-V (can be tied to REF_OUT terminals) the DAC range is -10 to 0-V. DAC_B7, 27, 29 DAC group B. These channels share the same range and clamp voltage. DAC_B6 Negative analog supply for DAC group B. Sets the power-on-reset and clamp voltage values. Typically tied to AVEE 28 AVSSB when the DAC range for group B is set to -10 to 0-V or AGND for the positive output ranges. 30 REF_OUT1 Reference output 1. Can be used to drive the VRANGE inputs. 31 AVDD1 Analog supply voltage. (+4.5-V to +5.5-V) 32 REF_CMP Internal reference compensation capacitor connection (connect 4.7- μF capacitor between this terminal and AGND2). Analog ground. Ground reference point for all analog circuitry on the device, AGND. Connect AGND1, AGND2 and 33 AGND2 AGND3 to the same potential, AGND. 34 AVDD2 Analog supply voltage. (+4.5-V to +5.5-V) ADC_11, ADC_10, Bipolar analog inputs. Typically used to monitor the DAC_A8 to DAC_A11 outputs. The input range of these channels 35-38 ADC_9, is -12.5-V to +12.5-V. ADC_8 ADC_7, Bipolar analog inputs. Typically used to monitor the DAC_B6 to DAC_B7 outputs. The input range of these channels 39-40 ADC_6 is -12.5-V to +12.5-V. 4 Submit Documentation Feedback Copyright © 2014, Texas Instruments Incorporated Product Folder Links: AMC7832 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |