35 / 60 page ![]() Once the current diagnostic cycle is over, a new cycle can be started with OPL ON diagnosis requested for a different channel. Figure 16. Open load at ON circuit 9.3.2 Open load at ON bit In the DIAG_OPL_ON register there are 8 bits that can assume the following values: • “0” = no Open Load at ON state detected, or the channel is OFF when the diagnosis is performed • “1” = Open Load at ON state detected This register is clear on read. An SPI read is necessary to clear the faulty information. Once the DIAG_OPL_ON flag is set, it remains asserted until a new diagnostic cycle is completed when the fault is no longer present, and the diagnostic register is read through SPI. L9026 Diagnosis DS13397 - Rev 9 page 35/60 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|