| 数据搜索系统,热门电子元器件搜索 |
|
CLP270M 数据表(PDF) 3 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
CLP270M 数据表(HTML) 3 Page - STMicroelectronics |
|
3 / 24 page ![]() CLP270M 3/24 APPLICATION NOTE 1. INTRODUCTION This device includes a primary protection level and is suitable for main distribution frames and line cards. This protection concept is explained and, in addition, the CLP270M performances are analysed when facing different surges as described in the BELLCORE GR 1089 recommendations. Figure 1 is a simplified block diagram of a subscriber line protection that is commonly used. This shows two different topologies : s A “primary protection” located on the Main Distribution Frame (MDF) eliminates coarsely the high energy environmental disturbances (lightning transients and AC power mains disturbances) s A “secondary protection” located on the line card includes a primary protection level (first stage) and a residual protection (second stage) which eliminates finely the remaining transients that have not been totally suppressed by the first stage. 2. STMicroelectronics CLP270M CONCEPT 2.1. Evolution of the SLIC protection Over the years, the silicon protection performances have considerably changed. The first generation of products like SMTHBTxx and SMTHDTxx offered fixed overvoltage protection against surges on either TIP or RING line in four packages. The following generation like THBTxx and THDTxx still offered fixed overvoltage protection against surges on both TIP and RING lines in two packages. The next step was the introduction of the LCP1511D which brought the advantage of full programmable voltage. Today, the CLP270M combines the features of all the previous generations. In addition to that, it offers an overcurrent detection when operating in speech mode and also a Failure Status output signal. CLP270M CLP270M SLIC SLIC THDTxx or LCP1511D or LCDP1511D “PRIMARY PROTECTION” “SECONDARY PROTECTION” “SECONDARY PROTECTION” Telecommunication line Telecommunication line MDF EXCHANGE EXCHANGE LINE CARD LINE CARD MDF Fig. 1: Subscriber line protection topology Line card operating conditions V I -I +I SWON SWON Programmable thanks to an external resistor Programmable thanks to any external voltage reference Fig. 2: Line card protection |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |