40 / 49 page ![]() SPI operation L9907 40/49 DS11800 Rev 5 3. SDO DIAG2 register - Diagnostic read cycle: B(15:13) = 111 Below, it is described the meaning of each diagnostic bit in case of DIAG2 active. a) SDO bit B9: BST_DIS_RB BST_DIS_RB informs about the status of that a BST_DIS pin (not cleared after read). b) SDO bit B8: EN1_RB EN1_RB informs about the status of EN1 filtered input (not cleared after read). c) SDO bit B7: AND(EN1,EN2)_RB AND(EN1,EN2)_RB informs about the status of AND(EN1,EN2) signal (not cleared after read). d) SDO bit B6: REGOFF_RB e) REGOFF_RB informs that a REG_OFF procedure has been triggered by EN1 lowering. Reading back this bit will re-engage FS_FLAG and cause REG_OFF='0'. f) SDO bit B5: BST_C_OV BST_C_OV informs about the status of boost over voltage level. Filter time duration: 16*tosc ≤ TFILT ≤ 20*tosc (active on both directions) effect when validated: BST_CLK = 0, BST_EN = 1, BST_HYST = 1, FS_FLAG = 0; EN_PWM[3:1] no change re-engagement: BST_CLK self re-engagement when fault disappears FS_FLAG re-engaged after DIAG2 reading and fault cleared g) SDO bit B4: GCR_OL GCR_OL informs about the status of the GCR pin open load condition (i.e. too high resistive value). Filter time duration: 16*tosc ≤ TFILT ≤ 20*tosc (active on both directions) effect when validated:GCR_INT_I = 1 re-engagement: GCR_INT_I = 0 self re-engagement when fault disappears FS_FLAG re-engaged after DIAG2 reading and fault cleared h) SDO bit B3: GCR_STG GCR_STG informs about the status of the GCR pin short to ground condition (i.e. too low resistive value). Filter time duration: 16*tosc ≤ TFILT ≤ 20*tosc (active on both directions) effect when validated:GCR_INT_I = 1 re-engagement: GCR_INT_I = 0 self re-engagement when fault disappears FS_FLAG re-engaged after DIAG2 reading and fault cleared i) SDO bit B<2:0>: SHT<X> Shoot Through on specific phase has occurred: FS_FLAG remains low till the fault is cleared by a read back of DIAG2 frame. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |