| 数据搜索系统,热门电子元器件搜索 |
|
L99PM72GXP 数据表(PDF) 21 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99PM72GXP 数据表(HTML) 21 Page - STMicroelectronics |
|
21 / 129 page ![]() DocID024767 Rev 4 21/129 L99PM72GXP Detailed description 128 To prevent the system from a deadlock condition (no wake up possible) a configuration where the periodic timer interrupt and wake up by LIN and HS CAN are disabled, is not allowed. The default configuration is entered for all wake-up sources in case of such an invalid setting. All wake-up events from V1_standby mode (except IV1 > ICMP) are indicated to the microcontroller by a low-pulse (duration: 56 µs) at RxDL/NINT or RxDC/NINT (see Table 3: CAN wake-up signalization) Wake-up from V1_standby by SPI Access might be used to check the interrupt service handler. 2.2.8 Wake up inputs The de-bounced digital inputs WU1...WU3 can be used to wake up the L99PM72GXP from standby modes. These inputs are sensitive to any level transition (positive and negative edge) For static contact monitoring, a filter time of 64µs is implemented at WU1-3. The filter is started when the input voltage passes the specified threshold. In addition to the continuous sensing (static contact monitoring) at the wake up inputs, a cyclic sense functionality is implemented. This feature allows periodical activation of the wake-up inputs to read the status of the external contacts. The periodical activation can be linked to Timer 1 or Timer 2 (see Section 2.2.9). The input signal is filtered with a filter time of 16 µs after a programmable delay (80 µs or 800 µs) according to the configured Timer On-time. A wake-up is processed if the status has changed versus the previous cycle. The Outputs OUT_HS and OUT1-4 can be used to supply the external contacts with the timer setting according to the cyclic monitoring of the wake-up inputs. If the wake-up inputs are configured for cyclic sense mode the input filter timing and input filter delay (WUx_filt in control register 2) must correspond to the setting of the High Side Output which supplies the external contact switches (OUTx in control register 0). In Standby Mode, the inputs WU1-3 are SPI configurable for pull-up or pull-down current source configuration according to the setup of the external. In active mode the inputs have a pull down resistor. In Active Mode, the input status can be read by SPI (Status Register 2). Static sense should be configured (Control Register 2) before the read operation is started (In cyclic sense IV1 >ICMP Device remains in V1_standby mode but watchdog is enabled (If ICMP =0) and the V1 regulator goes into High Current Mode (Increased Current Consumption). No interrupt is generated. Timer Interrupt / Wake up of µC by TIMER programmable by SPI –V1_standby Mode: device wakes up and Interrupt signal is generated at RxDL/NINT when programmable timeout has elapsed –VBat_standby Mode: device wakes up, V1 regulator is turned on and NRESET signal is generated when programmable timeout has elapsed SPI Access Always active (except in VBat_standby mode) Wake up event: CSN is low and first rising edge on CLK Table 4. Wake up from Standby Modes (continued) Wake up source Description |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |