| 数据搜索系统,热门电子元器件搜索 |
|
L99PM72GXP 数据表(PDF) 31 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99PM72GXP 数据表(HTML) 31 Page - STMicroelectronics |
|
31 / 129 page ![]() DocID024767 Rev 4 31/129 L99PM72GXP Detailed description 128 2.6 Reset output (NRESET) If V1 is turned on and the voltage exceeds the V1 reset threshold, the reset output “NRESET” is pulled up by internal pull up resistor to V1 voltage after a reset delay time (trd). This is necessary for a defined start of the micro controller when the application is switched on. Since the NRESET output is realized as an open drain output it is also possible to connect an external NRESET open drain NRESET source to the output. As soon as the NRESET is released by the L99PM72 the Watchdog timing starts with a long open window. A reset pulse is generated in case of: • V1 drops below VRTH (configurable by SPI) for t > tUV1 • watchdog failure • turn-on of the V1 regulator (VS power-on or wake-up from Vbat_standby mode) 2.7 Operational amplifiers The operational amplifiers are especially designed to be used for sensing and amplifying the voltage drop across ground connected shunt resistors. Therefore the input common mode range includes -0.2 V to 3V. The operational amplifiers are designed for -0.2 V to 3 V input voltage swing and rail-to-rail output voltage range. All pins (positive, negative and outputs) are available to be able to operate in non-inverting and inverting mode. Both operational amplifiers are on-chip compensated for stability over the whole operating range within the defined load impedance. The Operational Amplifiers may also be used to setup an additional high current voltage source with an external pass element. Refer to Section 2.1.3 for a detailed description. Table 7. Persisting fail safe conditions and exit modes Failure source Failure condition Diagnosis Exit from Fail_safe Mode µC (oscillator) 15 consecutive watchdog failures Fail_safe = 1; Forced_Sleep_WD = 1 Wake-up TRIG = 1 during LOWi Read & Clear SR3 V1 short at turn-on Fail_safe = 1; Forced_Sleep_TSD2_SHTV1 = 1 Read & Clear SR3 after wake-up Temperature 7 times TSD2 Fail_safe = 1; TW = 1; TSD1 = 1; TSD2 = 1; Forced_Sleep_TSD2_SHTV1=1 Read & Clear SR3 after wake-up |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |