| 数据搜索系统,热门电子元器件搜索 |
|
SAP5SD-A-G1-R 数据表(PDF) 47 Page - Zentrum Mikroelektronik Dresden AG |
|
|
|||||||||||||||||||||||||||||
SAP5SD-A-G1-R 数据表(HTML) 47 Page - Zentrum Mikroelektronik Dresden AG |
|
47 / 62 page ![]() SAP5S / SAP51 Universal Actuator-Sensor Interface IC Data Sheet July 17, 2012 © 2012 Zentrum Mikroelektronik Dresden AG — Rev. 3.1 All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The information furnished in this publication is PRELIMINARY and subject to changes without notice. 47 of 62 Note: The value of the Parameter Port P0 Input does not influence the watchdog activation at all. Only the master can change the activation status by sending a corresponding Write_Parameter (WPAR) request. This allows using the feature even if IO-Code 7 is selected. In this case, the parameter port pins are mapped into Data Input pins. But since the activation of the Communication Watchdog only depends on the value of the parameter output register, the watchdog functionality still remains controlled by the master. Watchdog activation through the value of Parameter Port P0 is not available in Safety Mode. Table 33: Activation of the SAP5 Communication Watchdog Lock_EE_PRG E²PROM flag Inhibit_Watchdog E²PROM flag P0_Watchdog_Activation E²PROM flag Safety_Mode _Enable Parameter Port P0 output reg Watchdog Activation 0 X X X X OFF 1 1 X X X OFF 1 0 0 X X ON 1 0 1 1 X ON 1 0 1 0 0 OFF 1 0 1 0 1 ON The Communication Watchdog recognizes a No Data Exchange status as soon as the following conditions come true together: The Communication Watchdog is activated. No DEXG or WPAR request was processed for more than 94.2ms (+4ms). Slave address is unequal to zero (0). No E²PROM write access is active. If the Communication Watchdog detects a No Data Exchange status, it takes the following actions: It concurrently generates Data and Parameter Strobe signals at the DSTBn an PSTBn pins with timing according to Figure 6 and Figure 7. NOTE: At this time, the data and parameter output values still comply with the values received with the last DEXG and WPAR master call, respectively. After DSTBn an PSTBn strobe generation finished, the Communication Watchdog invokes an unconditioned IC Reset. It sets the Data_Exchange_Disable flag and - afterwards - starts the IC initialization procedure, switching all Data and Parameter Outputs inactive. In order to resume to normal Data Port communication after a Watchdog IC Reset, the Data_Exchange_Disable flag must be cleared again. Therefore, the master has to send a WPAR request again before Data Port communication can be reestablished. This ensures new parameter setup of possibly connected external circuitry. The state until the Data_Exchange_Disable flag returns to ‘0’ is signaled by a certain LED1 and LED2 status indication (refer to 4.11). 4.18. Safety Mode Using the SAP5 Safety Mode makes it easy to implement a safety-related AS-i slave according to the AS-i Safety at Work concept. Slaves complying with the control category 4 according to EN 954 –1 can be implemented even with a minimum of external circuitry. The Safety Mode is active as soon as the E²PROM flag Safety_Mode_Enable is set to ‘1’ (logic HIGH). Thus, it is basically independent on the slave profile, whereas the assignment of the 3-level-input pins mentioned below to either the Data- or the Parameter port depends on the IO_Code as described in Table 26 on page 40. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |