7 / 22 page ![]() MLX90609 Angular Rate Sensor (Standard version) 390109060901 Page 7 of 22 Data Sheet Rev 008 February/08 Parameter Symbol Test Conditions Min Typ Max Units Resonance Frequency FRES 8.2 KHz Wake-up time at power up Note 2 MLX90609 operational, all parameters are in spec., CFLT=10nF, C3=100nF. Capacitors names are referred to Fig.6-1 150 250 ms Resolution of the internal ADC 11 bit ADC conversion time Note 2 TCONV Includes Track/Hold Acquisition Time 90 115 µs Voltage Reference VREF0 at 25°C 2.45 2.5 2.55 V Voltage Reference TC TCVREF VREF = VREF0 (1 + TCVREF × ∆T) 90 ppm/K Temperature Sensor VTEMP0 at 25°C 2.3 2.5 2.7 V Temperature Sensor TC TCTEMP VOUTTEMP = VTEMP0 + TCTEMP × ∆T 10 mV/K Table 4. Sensor Specific Specifications Notes: 1. Better performance can be obtained. Please contact Melexis. 2. These numbers are guaranteed by design and/or characterization. 3. The voltage reference should ideally not be loaded, as there is an internal ESD resistor of about 1.5 kOhm in series with the output. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|