| 数据搜索系统,热门电子元器件搜索 |
|
SP5669 数据表(PDF) 5 Page - Mitel Networks Corporation |
|
|
|||||||||||||||||||||||||||||
SP5669 数据表(HTML) 5 Page - Mitel Networks Corporation |
|
5 / 12 page ![]() 5 SP5669 byte. If the controller fails to pull the SDA line low during this period, the device generates an internal STOP condition, which inhibits further reading. WRITE MODE With reference to Table 1, bytes 2 and 3 contain frequency information bits 2 14 –2 0 inclusive. Auxillary frequency bits 2 16 –2 15 are in byte 4. For most frequencies only bytes 2 and 3 will be required. The remainder of byte 4 and byte 5 control the prescaler enable, reference divider ratio (see Fig. 3), charge pump, REF/COMP output (see Fig. 5), output ports and test modes (see Fig. 5). After reception and acknowledgement of a correct address (byte 1), the first bit of the following byte determines whether the byte is interpreted as a byte 2 or 4, a logic ’0’ indicating byte 2 and a logic ’1’ indicating byte 4. Having interpreted this byte as either byte 2 or 4 the following data byte will be interpreted as byte 3 or 5 respectively. Having received two complete data bytes, additional data bytes can be entered, where byte interpretation follows the same procedure, without readdressing the device. This procedure continues until a STOP condition is received. The STOP condition can be generated after any data byte, if however it occurs during a byte transmission, the previous data is retained. To facilitate smooth fine tuning, the frequency data bytes are only accepted by the device after all 17 bits of frequency data have been received, or after the generation of a STOP condition. Repeatedly sending bytes 2 and 3 only will not change the frequency. A frequency change occurs when one of the following data sequences is sent to an addressed device; Bit 2 (FL) indicates whether the device is phase locked, a logic ’1’ is present if the device is locked, and a logic ’0’ if the device is unlocked. Bits 6,7 and 8 (A2, A1, A0) combine to give the output of the ADC. The ADC can be used to feed AFC information to the microprocessor via the I 2 C bus. ADDITIONAL PROGRAMMABLE FEATURES Prescaler enable The divide by two prescaler is enabled by setting bit PE within byte 4 to a logic ’1’. A logic ’0’ disables the prescaler, directly passing the RF input frequency to the 17–bit programmable counter. Bit PE is a static select only. Charge pump current The charge pump current can be programmed by bits C1 and C0 within data byte 5, as defined in Fig. 6. Test mode The test modes are invoked by setting bits RE=0 and RTS=1 within the programming data, and are selected by bits TS2, TS1 and TS0 as shown in Fig. 5. When TS2, TS1 and TS0 are received, the device retains previously received P2, P1 and P0 data. Reference/Comparison frequency output The reference frequency F ref can be switched to the REF/ COMP output, pin 3, by setting bit RE=1 and RTS=0 within byte 5. The comparison frequency F comp can be switched to the REF/COMP output, pin 3, by setting bit RE=1 and RTS=1 within byte 5. For RE set to logic ’0’, the output is disabled and set to a high state. RE and RTS default to logic ’1’ during device power up, thus enabling the comparison frequency F comp at the REF/COMP output. Bytes 2, 3, 4, 5 Bytes 4, 5, 2, 3 or when a STOP condition follows valid data bytes as follows; Bytes 2, 3, 4, STOP Bytes 4, 5, 2 STOP Bytes 2, 3, STOP Bytes 2, STOP Bytes 4, STOP It should be noted that the device must be initially addressed with both frequency AND control byte data, since the control byte contains reference divider information which must be provided before a chosen frequency can be synthesised. This implies that after initial turn on, bytes 2, 3, 4 must be sent followed by a STOP condition as a minimum requirement. Alternatively bytes 2, 3, 4, 5 must be sent if port information is also required. READ MODE When the device is in read mode, the status byte read from the device takes the form shown in Table 2, Fig. 4. Bit 1 (POR) is the power–on reset indicator, and this is set to a logic ’1’ if the V CC supply to the device has dropped below 3V (at 25 °C), e.g. when the device is initially turned ON. The POR is reset to ’0’ when the read sequence is terminated by a STOP command. When POR is set high (at low V CC), the programmed information is lost and the output ports are all set to high impedance. Comparison frequency with a R3 R2 R1 R0 Ratio 4MHz external reference 0 0 0 0 2 2MHz 0 0 0 1 4 1MHz 0 0 1 0 8 500kHz 0 0 1 1 16 250kHz 0 1 0 0 32 125kHz 0 1 0 1 64 62.5kHz 0 1 0 0 128 31.25kHz 0111 256 15.625kHz 1 0 0 0 Not - Allowed 1 0 0 1 6 666.67kHz 1 0 1 0 12 333.33kHz 1011 24 166.67kHz 1 1 0 0 48 83.33kHz 1 1 0 1 96 41.67kHz 1 1 1 0 192 20.83kHz 1 1 1 1 384 10.42kHz Fig. 3 Reference division ratios |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |