| 数据搜索系统,热门电子元器件搜索 |
|
CP-C.1-A-RU 数据表(PDF) 2 Page - ABB |
|
|
|||||||||||||||||||||||||||||
CP-C.1-A-RU 数据表(HTML) 2 Page - ABB |
|
2 / 8 page ![]() 2 - Redundancy unit CP-C.1-A-RU | Data sheet Functions 1 INPUT 1, 2: Terminals – input 2 Circuit diagram 3 OUTPUT +/-, +/ –: Terminals – output Application The redundancy unit CP-C.1-A-RU provides decoupling of two CP-C.1-A-RU power supply units. It provides automatic redundant power supply operation for critical applications. It has 2 inputs, each up to 20 A, and 1 output up to 40 A. Operating mode True redundancy with decoupling provided by the CP-C.1-A-RU Redundant circuits are used to increase the operational reliability and eliminate power supply outages. Events that can cause a power supply failure include: incorrect wiring, blown fuses, or failure of a single power supply. If a fault event occurs (called initial fault) in the first power supply circuit, power to all loads is then supplied by the second (redundant) power supply. For this reason, both power supplies must be sized to handle the total current requirement of all loads. The primary and the redundant power supplies are decoupled from one another by the CP-C.1-A-RU unit. It automatically switches from the primary to the redundant supply after a fault. It decouples the output of the failed power supply from the redundant supply preventing the initial fault from shorting or compromising the redundant supplies’ output. In this way, uninterrupted supply of power to all loads is guaranteed. When available, the two power supplies should be connected to different input voltage phases, to avoid loss of power caused by a blown fuse on the primary side of the power supplies. True redundancy, Iout ≤ Ir 3 2 1 Functions, application, operating mode Parallel operation for increased power Another operation mode of two power supplies in combination with a redundancy unit is to parallel and decouple them for increased power. The setup looks similar to the true redundant installation above but the field of application is different. Instead of redundancy the max. output current (limits see under the schematics) can be used to power up the loads. The redundancy module decouples both power supplies from each other to avoid that any electrical failure from one power supply circuit affects the other one. However, using the increased power also means there is no redundancy since if one supply fails the other one can not supply the load alone. Increased power, Iout ≥ Ir CP-C.1 Ir 20 A CP-C.1 Ir 20 A L+ L+ L- L- CP-C.1-A-RU INPUT 1INPUT 2 ++ - - OUTPUT +- +- LN PE LN PE L1 L2 L3 N PE Load Iout Ir Ta 60 °C - max. 20 A Ta 40 °C - max. 30 A CP-C.1 Ir 20 A CP-C.1 Ir 20 A L+ L+ L- L- CP-C.1-A-RU INPUT 1INPUT 2 ++ - - OUTPUT +- +- LN PE LN PE L1 L2 L3 N PE Load Iout Ir Ta 60 °C - max. 40 A Ta 40 °C - max. 60 A |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |