| 数据搜索系统,热门电子元器件搜索 |
|
M50LPW040 数据表(PDF) 11 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M50LPW040 数据表(HTML) 11 Page - STMicroelectronics |
|
11 / 36 page ![]() 11/36 M50LPW040 Read Memory Array Command. The Read Mem- ory Array command returns the memory to its Read mode where it behaves like a ROM or EPROM. One Bus Write cycle is required to issue the Read Memory Array command and return the memory to Read mode. Once the command is is- sued the memory remains in Read mode until an- other command is issued. From Read mode Bus Read operations will access the memory array. While the Program/Erase Controller is executing a Program or Erase operation the memory will not accept the Read Memory Array command until the operation completes. Read Status Register Command. The Read Sta- tus Register command is used to read the Status Register. One Bus Write cycle is required to issue the Read Status Register command. Once the command is issued subsequent Bus Read opera- tions read the Status Register until another com- mand is issued. See the section on the Status Register for details on the definitions of the Status Register bits. Read Electronic Signature Command. The Read Electronic Signature command is used to read the Manufacturer Code and the Device Code. One Bus Write cycle is required to issue the Read Electronic Signature command. Once the command is issued subsequent Bus Read operations read the Manufacturer Code or the Device Code until a Read Memory Array command is issued. After the Read Electronic Signature Command is issued the Manufacturer Code and Device Code can be read using Bus Read operations using the addresses in Table 10. Program Command. The Program command can be used to program a value to one address in the memory array at a time. Two Bus Write operations are required to issue the command; the second Bus Write cycle latches the address and data in the internal state machine and starts the Program/Erase Controller. Once the command is issued subsequent Bus Read operations read the Status Register. See the section on the Status Register for details on the definitions of the Status Register bits. If the address falls in a protected block then the Program operation will abort, the data in the memory array will not be changed and the Status Register will output the error. During the Program operation the memory will only accept the Read Status Register command and the Program/Erase Suspend command. All other commands will be ignored. Typical Program times are given in Table 12. Note that the Program command cannot change a bit set at ‘0’ back to ‘1’ and attempting to do so will not cause any modification on its value. One of the Erase commands must be used to set all of the bits in the block to ‘1’. See Figure 14, Program Flowchart and Pseudo Code, for a suggested flowchart on using the Program command. Quadruple Byte Program Command. The Qua- druple Byte Program Command can be only used in A/A Mux mode to program four adjacent bytes in the memory array at a time. The four bytes must differ only for the addresses A0 and A1. Programming should not be attempted when VPP is not at VPPH. The operation can also be executed if VPP is below VPPH, but result could be uncertain. Five Bus Write operations are required to issue the command. The second, the third and the fourth Bus Write cycle latches respectively the address and data of the first, the second and the third byte in the internal state machine. The fifth Bus Write cycle latches the address and data of the fourth byte in the internal state machine and starts the Program/Erase Controller. Once the command is issued subsequent Bus Read operations read the Status Register. See the section on the Status Register for details on the definitions of the Status Register bits. During the Quadruple Byte Program operation the memory will only accept the Read Status register command and the Program/Erase Suspend com- mand. All other commands will be ignored. Typical Quadruple Byte Program times are given in Table 12. Note that the Quadruple Byte Program command cannot change a bit set to ‘0’ back to ‘1’ and attempting to do so will not cause any modification on its value. One of the Erase commands must be used to set all of the bits in the block to ‘1’. See Figure 15, Quadruple Byte Program Flow- chart and Pseudo Code, for a suggested flowchart on using the Quadruple Byte Program command. Chip Erase Command. The Chip Erase Com- mand can be only used in A/A Mux mode to erase the entire chip at a time. Erasing should not be at- tempted when VPP is not at VPPH. The operation can also be executed if VPP is below VPPH, but re- sult could be uncertain. Two Bus Write operations are required to issue the command and start the Program/Erase Controller. Once the command is issued subsequent Bus Read operations read the Table 10. Read Electronic Signature Note: For A19 value, refer to Table 2. Code Address Data Manufacturer Code 00000h 20h Device Code 00001h 26h |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |