| 数据搜索系统,热门电子元器件搜索 |
|
M59MR032C 数据表(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M59MR032C 数据表(HTML) 13 Page - STMicroelectronics |
|
13 / 49 page ![]() 13/49 M59MR032C, M59MR032D Auto Select (AS) Instruction. This instruc- tion uses two Coded Cycles followed by one write cycle giving the command 90h to address 555h for command set-up. A subsequent read will output the Manufacturer or the Device Code (Electronic Signature), the Block Protection status or the Con- figuration Register status depending on the levels of ADQ0 and ADQ1 (see Tables 9, 10 and 11). The Electronic Signature can be read from the memory allowing programming equipment or ap- plications to automatically match their interface to the characteristics of M59MR032. The Manufac- turer Code is output when the address lines ADQ0 and ADQ1 are at VIL, the Device Code is output when ADQ0 is at VIH with ADQ1 at VIL. The codes are output on ADQ0-ADQ7 with ADQ8- ADQ15 at 00h. The AS instruction also allows the access to the Block Protection Status. After giving the AS instruction, ADQ0 is set to VIL with ADQ1 at VIH, while A12-A20 define the address of the block to be verified (see Table 10). The AS Instruc- tion finally allows the access to the Configuration Register status if both ADQ0 and ADQ1 are set to VIH; refer to Table 12 for configuration register de- scription. A reset command puts the device in Read Array mode. Write Configuration Register (CR) Instruc- tion. This instruction uses two Coded Cycles fol- lowed by one write cycle giving the command 60h to address 555h. A further write cycle giving the command 03h writes the contents of address bits ADQ0-ADQ15 to bits CR15-CR0 of the configura- tion register. At Power-up the Configuration Reg- ister is set to asynchronous Read mode, Power- down disabled and bus invert (power save func- tion) disabled. A description of the effects of each configuration bit is given in Table 12. Table 12. Read Configuration Register (AS and Read CFI instructions) Configuration Register Function CR15 Read mode 0 = Burst mode read 1 = Page mode read (default) CR14 Bus Invert configuration (power save) 0 = disabled (default) 1 = enabled CR13-CR11 X-Latency 010 = 2 clock latency 011 = 3 clock latency 100 = 4 clock latency 101 = 5 clock latency 110 = 6 clock latency CR10 Power-down configuration 0 = power-down disabled (default) 1 = power-down enabled CR9 Data hold configuration 0 = data output at every clock cycle 1 = data output every 2 clock cycles CR8 Wait configuration 0 = WAIT is active during wait state 1 = WAIT is active one data cycle before wait state CR7 Burst order configuration 0 = Interleaved 1 = Linear CR6 Clock configuration 0 = Address latched and data output on the falling clock edge. 1 = Address latched and data output on the rising clock edge. CR5-CR3 Reserved CR2-CR0 Burst length 001 = 4 word burst length 010 = 8 word burst length 111 = Continuous burst mode (requires CR7 = 1) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |