17 / 26 page ![]() www.austriamicrosystems.com/LED-Driver-ICs/AS1113 Revision 1.04 15 - 24 AS1113 Datasheet - D e t a i l e d D e s c r i p t i o n Detailed Shorted-LED Error Report The detailed shorted-LED error report can be read out immediately after global error mode has been run (see Global Error Mode on page 11). SDI must be 1 for the first device. Figure 15. Detailed Shorted-LED Error Report Timing Diagram Detailed Shorted-LED Error Report Example Consider a case where three AS1113s are cascaded in one chain. A 1 indicates a LED is on, a 0 indicates a LED is off, and an X indicates a shorted LED. This test is used on-the-fly. IC1:[11111XX111111111] IC2:[1111111111111111] IC3:[X100011111111111] IC1 has two shorted LEDs which are switched on, IC3 has one shorted LED switched off due to input. 3*16 clock cycles are needed to write the entire error code out. The detailed error report would look like this: Showing IC1 as the device with two shorted LEDs at position 6 and 7, and IC3 with one shorted LED at position 1. The shorted LED at position 1 of IC3 cannot be detected, since LEDs turned off at test time are not tested and will show a logic "1" at the detailed error report. To test all LEDs this test should be run with an all 1s test pattern. For a test with an all on test pattern, low-current diagnostic mode should be entered first to reduce on-screen flickering. Note: In an actual report there are no spaces in the output. LEDs turned off during test time cannot be tested and will show a logic 1 in the detailed error report. Low-Current Diagnostic Mode To run the open- or shorted-LED test, a test pattern must be used that will turn on each LED to be tested. This test pat- tern will cause a short flicker on the screen while the test is being performed. The low-current diagnostic mode can be initiated prior to running a detailed error report to reduce this on-screen flickering. Note: Normally, displays using such a diagnostic mode require additional cables, resistors, and other components to reduce the current. The AS1113 has this current-reduction capability built-in, thereby minimizing the number of external components required. Low-current diagnostic mode can be initiated via 3 clock pulses during error-detection mode. After the falling edge of LD, a test pattern displaying all 1s can be written to the shift register which will be used for the next error-detection test. Input Data: 1 11 1111 1111 111 11 1 1111 111 1111 1111 01 0001 1111 111 111 LED Status: 1 11 11X X 1111 111 11 1 1111 111 1111 1111 X 1 1111 1111 111 111 Failure Code: 1 11 1100 1111 111 11 1 1111 111 1111 1111 11 1111 1111 111 111 Global Flag Readout Detailed Error Report Readout SDI OEN LD CLK SDO tH(L) tSU(ERROR) tP1 tSW(ERROR) tP4 TFLAG SFLAG DBit14 DBit13 DBit12 DBitn DBit2 DBit1 DBit0 Don’t Care Don’t Care SBit14 SBit13 SBit12 SBitn SBit2 SBit1 SBit0 SBit15 New Data Input Shorted-LED Error Report Output OFLAG TFLAG tP4 tTESTING Global Flag Readout DBit15 For detailed timing information see Timing Diagrams on page 9. tGSW(ERROR) tGSW(ERROR) tGSW(ERROR) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |