| 数据搜索系统,热门电子元器件搜索 |
|
AS1113 数据表(PDF) 19 Page - ams-OSRAM AG |
|
|
|||||||||||||||||||||||||||||
AS1113 数据表(HTML) 19 Page - ams-OSRAM AG |
|
19 / 26 page ![]() www.austriamicrosystems.com/LED-Driver-ICs/AS1113 Revision 1.04 17 - 24 AS1113 Datasheet - A p p l i c a t i o n I n f o r m a t i o n 9 Application Information Error Detection The AS1113 features two types of error detection. The error detection can be used on-the-fly, for active LEDs, without any delay, or by entering into low-current diagnosis mode. Error Detection On-The-Fly Error detection on-the-fly will output the status of active LEDs during operation. Without choosing an error mode this will output the temperature flag at every input/output cycle. Triggering one clock pulse for open or two clock pulses for short detection during error detection mode outputs the detailed open- or short-error report with the next input/output cycle (see Figure 18). LEDs turned off at test time are not tested and will show a logic "1" at the detailed error report. Figure 18. Normal Operation with Error Detection During Operation – 64 Cascaded AS1113s Error Detection with Low-Current Diagnosis Mode This unique feature of the AS1113 uses an internal all 1s test pattern for a flicker free diagnosis of all LEDs. This error detection mode can be started at the end of each input cycle (see Figure 19). Figure 19. Low-Current Diagnosis Mode with Internal All 1s Test Pattern – 64 Cascaded AS1113s Display SDI SDO CLK OEN LD Current Data1 Data2 Data3 Data2 Data3 Data4 T/O or S Error Code Data1 T/O or S Error Code Data0 T/O or S Error Code Data2 1024x 1024x 1024x Clock for Error Mode 0x/1x/2x Rising Edge of OEN Acquisition of Error Status Falling Edge of LD; Error Register is copied into Shift Register ≤ 50mA GEF GEF GEF = Global Error Flag Falling Edge of LD; Error Register is copied into Shift Register Clock for Error Mode 0x/1x/2x Rising Edge of OEN Acquisition of Error Status Clock for Error Mode 1x/2x 3x Clocks Low- Current Mode 1024x 1024x Data0 Rising Edge of OEN Acquisition of Error Status Falling Edge of LD; Error Register is copied into Shift Register GEF O or S Error Code from All 1s Test Pattern Temperature Error Code Use Internal All 1s Test Pattern ≤ 50mA ≤ 50mA SDI SDO CLK OEN LD ≤ 0.8mA GEF = Global Error Flag 1024x Data1 Data2 Data2 Data3 T/O or S Error Code Data0 GEF Display Current Low-Current Diagnosis Mode Data1 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |