15 / 51 page ![]() STMPE1208S Capacitive sensors 15/51 5.2 Capacitance compensation The STMPE1208S is capable to measuring up to 7.2 pF in capacitance difference between the reference point (Zref) and the individual channels. In the case where the PCB connection between the sensor pads and the device is too long, the "REFERENCE DELAY" register is able to shift the reference by up to 6.0 pF, allowing the TOUCH channels to measure added capacitance 7.2 pF with offset of 6.0 pF, as shown in following diagram. In case this is still not enough to compensate for the capacitance on sensor lines (due to very long sensor trace), an external capacitor of up to 30 pF can be connected at the A_Ref pin. This allows to further shift up the dynamic range of the capacitance measurement. Figure 10. Capacitance compensation The sensed capacitance is accessible to host through the "IMPEDANCE" registers. 5.3 Setting of TVR and EVR The STMPE1208S uses 2 main parameters to control the sensitivity and calibration of the capacitive sensing system. TVR (touch variance) is a channel-specific value, that specifies the number of steps the sensed capacitance must be above the internal reference, to be considered a touch. Generally, this should be set as 4 −10, but it must be bigger than EVR. The EVR (environment variance) is a shared value that is applied to all the channels. This specifies the maximum change in capacitance that can be considered due to the shifting of the environmental factor. Generally, this should be set to 1 −5, but it must be less than TVR. Environment tracking calibration On power up, a calibration is executed. The initial calibration takes about 150 clock cycles of sensor clock for completion. Using 5 kHz sensor clock, this would be 30 mS. However, if any of the sensors are touched during powering up, calibration is delayed, until all sensors are untouched. In this case, the time taken for calibration, from the time when all sensors are untouched is: 2 * calibration interval + 150 * sensor clock period Increasing capacitance 30.0pF Reference delay register = 0 Dynamic range = 0 - 7.2 pF Reference delay register = 6.0 pF Dynamic range = 6.0 - 13.2 pF Reference delay = 6.0 pF S_REF external capacitance = 30 pF Dynamic range = 36 - 43.2 pF 6.0 pF 7.2 pF 6.0 pF 7.2 pF 7.2 pF CS00043 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |