| 数据搜索系统,热门电子元器件搜索 |
|
LED7707TR 数据表(PDF) 23 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
LED7707TR 数据表(HTML) 23 Page - STMicroelectronics |
|
23 / 48 page ![]() LED7707 Operation description 23/48 5.3.1 FAULT pin The FAULT pin is an open-collector output, (with 4 mA current capability) active low, which gives information regarding faulty conditions eventually detected. This pin can be used either to drive a status LED or to warn the host system. The FAULT pin status is strictly related to the MODE pin setting (see Table 7 for details). 5.3.2 MODE pin The MODE pin is a digital input and can be connected to AVCC or SGND in order to choose the desired fault detection and management. The LED7707 can manage a faulty condition in two different ways, according to the application needs. Table 7 summarizes how the device detects and handles the internal protections related to the boost section (over- current, over-temperature and over-voltage) and to the current generators section (open and shorted LEDs). 5.3.3 Open LED fault In case a row is not connected or a LED fails open, the device has two different behaviors according to the MODE pin status. If the MODE pin is high (i.e. connected to AVCC), the FAULT pin is set high as soon as the device recognizes the event; the open row is excluded from the control loop and the device continues to work properly with the remaining rows. Thus, if less than six rows are used in the application, the MODE pin must be set high. Connecting the MODE pin to SGND, the LED7707 behaves in a different manner: as soon as an open row is detected the FAULT pin is tied low and the device is turned off. The internal logic latches this status: to restore the normal operation, the device must be restarted by toggling the EN pin or performing a Power-On Reset (POR occurs when the voltage at the LDO5 pin falls below the lower UVLO threshold and subsequently rises above the upper one). Figure 16 shows an example of open channel detection in case of MODE connected to AVCC. Table 7. Faults management summary FAULT MODE to GND MODE to VCC Internal MOSFET over-current FAULT pin HIGH Power MOS turned OFF Output over-voltage FAULT pin LOW Device turned OFF, latched condition Thermal shutdown FAULT pin LOW. Device turned OFF. Automatic restart after 30 C temperature drop. LED short circuit “FAULT pin LOW, Device turned OFF (100s masking time), latched condition (Vth = 4.0 V)” - Open row(s) FAULT pin LOW Device turned OFF at first occurrence, latched condition FAULT pin HIGH faulty row(s) disconnected. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |