| 数据搜索系统,热门电子元器件搜索 |
|
TDF8599 数据表(PDF) 15 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
TDF8599 数据表(HTML) 15 Page - NXP Semiconductors |
|
15 / 52 page ![]() TDF8599_1 © NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 — 13 November 2008 15 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 8.5 Protection The TDF8599 includes a range of built-in protection functions. How the TDF8599 handles the various possible fault conditions differs for each protection and is described in the following sections: 8.5.1 Thermal foldback Thermal Foldback Protection (TFP) is activated when the junction temperature exceeds the threshold level (145 °C). TFP decreases amplifier gain such that the combination of dissipation and Rth(j-a) create a junction temperature around the threshold level. The device will not completely switch off but remains operational at the lower output power levels. If the junction temperature continues to increase, a second built-in temperature protection threshold level shuts down the amplifier completely. 8.5.2 Overtemperature protection If the junction temperature Tj > 160 °C, the OverTemperature Protection (OTP) is activated and the power stage immediately shuts down. 8.5.3 Overcurrent protection OverCurrent Protection (OCP) is activated when the output current exceeds the maximum output current of 8 A. OCP regulates the output voltage such that the maximum output current is limited to 8 A. The amplifier outputs keep switching and the amplifier is NOT shutdown completely. This is called current limiting. OCP also detects when the loudspeaker terminals are short circuited or one of the amplifier’s demodulated outputs is short circuited to one of the supply lines. In either case, the shorted channel(s) are switched off. The amplifier can distinguish between loudspeaker impedance drops and a low-ohmic short across the load or one of the supply lines. This impedance threshold depends on the supply voltage used. When a short is made across the load causing the impedance to drop below the threshold level, the shorted channel(s) are switched off. They try to restart every 50 ms. If the short circuit condition is still present after 50 ms, the cycle repeats. The average dissipation will be low because of this forced reduced duty cycle. When a channel is switched off due to a short circuit on one of the supply lines, Window Protection (WP) is activated. WP ensures the amplifier does not start-up after 50 ms until the supply line short circuit is removed. Table 9. Overview of protection types Protection type Reference Thermal foldback Section 8.5.1 Overtemperature Section 8.5.2 Overcurrent Section 8.5.3 Window Section 8.5.4 DC Offset Section 8.5.5 Undervoltage Section 8.5.6 Overvoltage Section 8.5.6 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |