| 数据搜索系统,热门电子元器件搜索 |
|
TC520ACPD 数据表(PDF) 6 Page - TelCom Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
TC520ACPD 数据表(HTML) 6 Page - TelCom Semiconductor, Inc |
|
6 / 8 page ![]() 3-44 TELCOM SEMICONDUCTOR, INC. 4 µsec makes the SYSCLK frequency equal to 250kHz. This makes the external crystal (or fre- quency source) equal to 1.0MHz (since SYSCLK = crystal frequency/4). Calculating integration time (in msec) using TSYSCLK = 4µsec, TINT = µsec x 32768 = 131msec. (4) Calculate Load Value Plug the TINT and TSYSCLK values into the equa- tion and convert the resulting value to hexadeci- mal: LOAD VALUE = [(65536 - (TINT/TSYSCLK)] 256 In this example, LOAD VALUE = 128(10) = 10H. There- fore, a LOAD VALUE of 10H is loaded to the TC520A. If the desired TINT was 100msec instead of 131msec, the LOAD VALUE would be 9EH, and so on. The TC520A LOAD VALUE must be initialized on power-up, and can be re- initialized as often as desired thereafter. This is accom- plished by bringing the LOAD input low while transmitting the appropriate LOAD VALUE to the TC520A as shown in Figure 1 and Figure 2. Polled vs. Interrupt Operation The TC520A can be accessed at any time by the host microprocessor. This makes operation in a polled environ- ment especially easy since the most recently converted data is available to the processor as needed. The TC520A can also be used in an interrupt environment by connecting DV to the IRQ line of the processor. Since AZ is the first phase of a new conversion cycle, the most recently converted data will be available as soon as DV goes low. If so desired, the interrupt service routine can also modify the LOAD VALUE during the DV = low interval. Opto-Isolated Applications The 3 wire serial port of the TC520A can be opto- isolated for applications requiring isolated data acquisition. The additional control lines (LOAD, DV, READ) are normally not needed in such applications, but can also be brought across the isolation barrier with the addition of a second isolator. Figure 1. TC520A Initialization and Start/Stop Conversion Timing Relationships LOAD LOAD VALUE updated and conversion started TC520A CONVERSION STATE CE is pulled high only when during AZ (DV = LOW) New LOAD VALUE can be loaded (if so desired) TC520A held in AZ phase as long as CE = HIGH CE AZ INT IZ DINT AZ INT INT DINT IZ AZ AZ DIN, DCLK DV LOAD VALUE shifted into DIN LOAD VALUE TC520A SERIAL INTERFACE ADAPTER FOR TC500 A/D CONVERTER FAMILY |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |