| 数据搜索系统,热门电子元器件搜索 |
|
M24LR64-R 数据表(PDF) 15 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M24LR64-R 数据表(HTML) 15 Page - STMicroelectronics |
|
15 / 126 page ![]() M24LR64-R Signal description Doc ID 15170 Rev 9 15/126 2.6 Supply voltage (VCC) 2.6.1 Operating supply voltage VCC Prior to selecting the memory and issuing instructions to it, a valid and stable VCC voltage within the specified [VCC(min), VCC(max)] range must be applied (see Table 100). In order to secure a stable DC supply voltage, it is recommended to decouple the VCC line with a suitable capacitor (usually of the order of 10 nF to 100 nF) close to the VCC/VSS package pins. This voltage must remain stable and valid until the end of the transmission of the instruction and, for a Write instruction, until the completion of the internal I²C write cycle (tW). 2.6.2 Power-up conditions When the power supply is turned on, VCC rises from VSS to VCC. The VCC rise time must not vary faster than 1V/µs. 2.6.3 Device reset In order to prevent inadvertent write operations during power-up, a power-on reset (POR) circuit is included. At power-up (continuous rise of VCC), the device does not respond to any instruction until VCC has reached the power-on reset threshold voltage (this threshold is lower than the minimum VCC operating voltage defined in Table 100). When VCC passes over the POR threshold, the device is reset and enters the Standby Power mode, however, the device must not be accessed until VCC has reached a valid and stable VCC voltage within the specified [VCC(min), VCC(max)] range. In a similar way, during power-down (continuous decrease in VCC), as soon as VCC drops below the power-on reset threshold voltage, the device stops responding to any instruction sent to it. 2.6.4 Power-down conditions During power-down (continuous decay of VCC), the device must be in Standby Power mode (mode reached after decoding a Stop condition, assuming that there is no internal write cycle in progress). Figure 4. I2C Fast mode (fC = 400 kHz): maximum Rbus value versus bus parasitic capacitance (Cbus) 1 10 100 10 100 1000 Bus line capacitor (pF) When tLOW = 1.3 µs (min value for fC = 400 kHz), the Rbus × Cbus time constant must be below the 400 ns time constant line represented on the left. I²C bus master M24xxx Rbus VCC Cbus SCL SDA ai14796b R bus × C bus = 400 ns Here Rbus × Cbus = 120 ns 4 k Ω 30 pF |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |