33 / 62 page ![]() © 2009 Microchip Technology Inc. DS22153C-page 33 MCP9843/98243 5.2.3.1 Comparator Mode Comparator mode is selected using bit 0 of CONFIG. In this mode, the Event output is asserted as active-high or active-low using bit 1 of CONFIG. Figure 5-12 shows the conditions that toggle the Event output. If the device enters Shutdown mode with asserted Event output, the output will de-assert. It will remain de- asserted until the device enters Continuous Conver- sion mode and after the first temperature conversion is completed, tCONV. After the initial temperature conver- sion, TA must satisfy the TUPPER or TLOWER boundary conditions in order for Event output to be asserted. Comparator mode is useful for thermostat-type applications, such as turning on a cooling fan or triggering a system shutdown when the temperature exceeds a safe operating range. 5.2.3.2 Interrupt Mode In the Interrupt mode, the Event output is asserted as active-high or active-low (depending on the polarity configuration) when TA drifts above or below TUPPER and TLOWER limits. The output is deasserted by setting bit 5 (Interrupt Clear) of CONFIG. If the device enters Shutdown mode with asserted Event output, the output will de-assert. It will remain de-asserted until the device enters Continuous Conversion mode and after the first temperature conversion is completed, tCONV. If the inter- rupt clear bit (Bit 5) is never set, then the Event output will re-assert after the first temperature conversion. In addition, if TA >= TCRIT the Event output is forced as Comparator mode and asserts until TA < TCRIT - THYST. While the Event output is asserted, user must send Clear Interrupt command (bit 5 of CONFIG) for Event output to de-assert, when temperature drops below the critical limit, TA < TCRIT - THYST. Otherwise, Event output remains asserted (see Figure 5-12 for graphical descrip- tion). Switching from Interrupt mode to Comparator mode also de-asserts Event output. This mode is designed for interrupt driven microcontroller based systems. The microcontroller receiving the interrupt will have to acknowledge the interrupt by setting bit 5 of CONFIG register from the MCP9843/98243. 5.2.4 TEMPERATURE RESOLUTION The MCP9843/98243 device is capable of providing a temperature data with 0.5°C to 0.0625°C resolution. The Resolution can selected using the Resolution register (Register 5-9) which is located in address ‘00001000’b. This address location is not specified in JEDEC Standard JC42.4. However, it provides additional flexibility while being functionally compatible with JC42.4 and provide a 0.25°C resolution at 125 ms (max.). The selected resolution can be read by user using bit 4 and bit 3 of the Capability register (Register 5-2). A 0.25°C resolution is set as POR default by factory. TABLE 5-2: TEMPERATURE CONVERSION TIME Resolution tCONV (ms) Samples/sec (typical) 0.5°C 30 33 0.25°C (Power-up default) 65 15 0.125°C 130 8 0.0625°C 260 4 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |